Open Channel Flow Meter (Ultrasonic Open Channel Flow Meter) measures the flow, cumulative volume and water level of liquids in open channels online. With IP65/IP68 protection, it is widely used for sewage, irrigation and industrial drainage....
The Ultrasonic Open Channel Flow Meter is suitable for long-term online measurement of various liquid flows. The main unit has a protection rating of IP65 and the sensor has IP68. The main unit and sensor are installed separately; the main unit can be installed indoors, in an instrument cabinet or on an instrument panel, and the sensor is installed on a measuring bracket. The main unit and sensor are connected by a dedicated ultrasonic cable. It can achieve precise measurement of instantaneous flow, cumulative flow and liquid level height.
It is widely used in sewage treatment, agricultural irrigation, domestic wastewater discharge, water conservancy, metallurgy, chemical engineering, aquaculture, rivers, energy and other industries. It can also be used for production monitoring, water balance commissioning and energy-saving monitoring, and is an important flow measurement instrument in the production process.
1. Equipped with a high-resolution color LCD and a nearly 7-hour data-to-graph function, making data more intuitive and clearer;
2. Wide compatibility; suitable for all standard channel and flume types;
3. Reliable stability, capable of long-term online measurement with maintenance-free operation;
4. Internal parameters such as the blind zone support manual modification, allowing shielding of nearby interference sources;
5. The sensor has a built-in temperature sensor, achieving real-time temperature compensation of measured values for more accurate measurement;
6. Supports 485 communication / 4-20 mA analog output / HART protocol / NB, GPRS, LORA communication (optional functions);
| Item | Specification |
|---|---|
| Liquid Level Range | ≤5 m |
| Instantaneous Flow | Determined by the specification of the weir/flume used |
| Cumulative Flow | 0-999999 m³ |
| Resolution | 0.1 m³ or 0.1 L/s |
| Accuracy | 1-3% channel/flume accuracy |
| Blind Zone | 0.3-0.5 m |
| Scattering Angle | 6-12° |
| Temperature Compensation | Automatic temperature compensation |
| Output | 4-20 mA / relay / RS-485 |
| Power Supply Voltage | AC220V or DC24V (choose one) |
| Working Temperature | -20 - 70 ℃ |
| Protection Rating | IP65 (transmitter), IP68 (sensor) |
| Ambient Humidity | <85% |
| Installation Method | Bracket installation, flange installation |
| Cable Length | 10 m standard; dedicated ultrasonic cable used, signal transmission distance can be extended by more than 200 m |