Products

Model:
HD-AAS4H
Introduction:
Atomic Absorption Spectrometer (Flame Atomic Absorption Spectrophotometer) measures trace and ultra-trace elements with high precision. Widely used in geology, metallurgy, medicine, chemical, petroleum, agriculture, environmental protection and commodity inspection....
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
The flame atomic absorption spectrophotometer offers high analysis precision and a thoughtful humanized design, fully meeting the various specific needs of different customers. A graphite furnace controller, autosampler, hydride generator, etc. can be optionally configured according to different analysis needs.
It can be widely used in geology, metallurgy, medicine, chemical industry, petroleum, agriculture, environmental protection, commodity inspection and other industries. For the analysis of trace and ultra-trace elements, in recent years it has gradually expanded from inorganic chemistry to organic chemistry.
1. Four, six or eight lamp positions selectable: automatic three-dimensional switching, energy balancing, simultaneous preheating of multiple lamp positions to save waiting time; deuterium lamp background correction and high-performance element lamps can be selected.
2. Automatic instrument setting optimization: instrument setting automatic optimization and memory function, one-key completion of scanning peak finding.
3. Data report multi-format saving and printing output: convenient for data query and comparison.
4. Software design makes operation simpler: the instrument software adopts a single-interface multi-functional window design, real-time monitoring of data changes, support for mainstream Windows operating systems, support for remote control and calibration, Chinese/English versions optional.
5. Advanced and reliable multiple safety protection system: automatically detecting and alarming on abnormal conditions such as insufficient pressure, gas leakage and flameout.
6. Expansion and coupling functions: hydride system, graphite furnace system and coupling functions.
7. Automatic online detection function.
| Detector | Hamamatsu photomultiplier tube (Japan) |
| Wavelength range | 185 nm-900 nm |
| Wavelength indication error | ≤±0.1 nm |
| Wavelength repeatability | ±0.025 nm |
| Baseline drift | 0.003 ABS/30 min (static); 0.005 ABS/15 min (dynamic) |
| Spectral bandwidth deviation (resolution) | At Cu 324.7 nm, 0.2 nm bandwidth, half-width 0.2 nm ±0.01 nm |
| Light source system | Turret-type fully automatic lamp-changing rack |
| Element lamp ignition mode | 400 Hz, 1/4 duty cycle pulse ignition |
| Lamp current adjustment | (0-10) mA (average current), software-adjustable |
| Monochromator type | Czerny-Turner enhanced type |
| Grating line density | 1800 lines/mm |
| Spectral bandwidth | 0.1 nm, 0.2 nm, 0.4 nm, 1.0 nm multi-stage automatic switching |
| Lamp holder | Turret-type automatic lamp-changing rack |
| Lamp power supply mode | 400 Hz, 1/4 duty cycle pulse ignition |
| Lamp current adjustment range | (0~10) mA (average current), software-adjustable |
| Characteristic concentration | (Cu) 0.025 µg/mL / 1% |
| Detection limit | (Cu) 0.006 µg/mL |
| Burner | 0.5 mm × 100 mm all-titanium burner |
| Repeatability | RSD ≤0.5% |
| Nebulizer | Metal-sleeve high-efficiency glass nebulizer |
| Atomization chamber | Corrosion-resistant all-plastic atomization chamber |
| Safety protection | Multiple automatic safety protection functions, acetylene leakage alarm, system shutdown |
| Measurement method | Air-acetylene flame method |
| Concentration calculation | Linear regression automatic working curve fitting, automatic result calculation |
| Repeat measurement times | 1~99 times, automatic calculation of the average and content, giving standard deviation and relative standard deviation |
| Result output | Multi-format data storage and printout |
| Communication interface | Standard RS232, USB expansion interface |
| Software environment | Fully compatible with Windows operating systems, professional Chinese software |
| Functional expansion | Hydride system and graphite furnace system |
| Power supply | AC 220 V/50 Hz |
| Power | 150 W |
| Working environment temperature | 10 ℃~35 ℃ |
| Working environment humidity | ≤80% |
| Dimensions | 1000 mm (L) × 400 mm (W) × 470 mm (H) |
| Weight | 70 kg |
Products
Services
About
Contact
Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.
008619053605658