Products

Model:
HD-SX100P
Introduction:
Handheld Multi-parameter Water Quality Analyzer measures COD, ammonia nitrogen, total phosphorus, total nitrogen, heavy metals and dozens of indicators with a multi-wavelength optical system. Widely used for field multi-parameter water analysis....
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
This product is a complete handheld water quality testing system consisting of a handheld main unit, a multi-purpose accessory case and dedicated accessories, designed for fast and flexible on-site multi-parameter water quality analysis. The light, portable main unit integrates a multi-wavelength optical detection system, a touch screen and a data transmission module, and can independently perform rapid colorimetric determination of dozens of parameters including COD, ammonia nitrogen, total phosphorus, total nitrogen and various heavy metals. To close the on-site testing loop, the accessory case contains two key accessories as standard: a high-capacity mobile power supply and a Bluetooth thermal printer. The power supply drives the matching 6-position smart digester so that digestion can be completed where no mains power is available, while the Bluetooth printer supports immediate wireless printing of results, integrating testing and reporting on site. This split design keeps the main unit portable while consolidating professional field laboratory and data output capability in the accessory case.
The instrument performs quantitative water quality analysis on the principle of multi-wavelength spectrophotometry. The main unit contains a multi-wavelength LED light source system with the analytical wavelength preset for each parameter. The user applies the supplied pre-prepared reagent to develop colour in the sample; parameters that do not require digestion (for example some heavy metals and ammonia nitrogen) can be measured directly with the main unit, while parameters requiring digestion (COD, total phosphorus, total nitrogen and some heavy metals) are first digested at high temperature in the digester, then developed and measured. According to the Lambert-Beer law the main unit automatically matches the stored standard curve and calculates the concentration directly.
Industrial wastewater: influent, process units and outfall monitoring at wastewater treatment stations in electroplating, printing and dyeing, pharmaceutical and food processing plants.
Municipal sewage: influent, biological units, effluent and reuse water inspection at wastewater treatment plants.
Environmental water bodies: rivers, lakes, reservoirs and wetlands, groundwater monitoring wells and private water sources — routine monitoring and pollution screening.
Drinking water safety: drinking water source protection areas, backup sources and rural centralised water supply facilities.
Enforcement and emergency response: surprise sampling at enterprise outfalls, park outfall patrols, on-site screening of sudden water pollution incidents and pollution plume tracking.
Research and teaching: water quality research, process optimisation and on-site testing and data collection for teaching experiments.
1. Android-based operating system with an elegant, user-friendly interface.
2. 4.3-inch HD touch screen with visual graphical pages, greatly improving operating efficiency.
3. High-reliability imported LED light source requiring no warm-up and offering long-term stability.
4. 10 mm × 10 mm large-area photocell for high sensitivity and a low detection limit.
5. The instrument offers both transmission (routine parameters) and scattering (turbidity) measuring modes.
6. 16 GB internal memory for more than 10,000 records; an optional Bluetooth printer allows results to be printed on site.
7. Wi-Fi and Bluetooth, plus a USB port for direct high-speed batch upload to a PC.
8. Water-resistant housing; the measuring chamber resists ingress of 0.5 mL of liquid.
9. Standard USB-C 5 V 2.1 A with BC 2.1 charging protocol support — compatible with third-party phone chargers, cables and power banks; intelligent lithium battery charge management allows long periods of mains-powered operation.
10. Bilingual Chinese/English operating system.
| Measuring method | Transmission + scattering |
| Light source | LED |
| Light source wavelengths | 420, 470, 520, 560, 620, 700, 860 nm |
| Absorbance range | −3.0 to 3.0 Abs |
| Absorbance resolution | 0.001 Abs |
| Optical stability | ≤ 0.002 Abs/30 min |
| Indication error (RE) | Not exceeding ±10 %; not exceeding ±5 % for some items |
| Repeatability (RSD) | ≤ 3 % |
| Detection items | See the appendix; reagents are optional |
| Protection class | IP 65 |
| Operating environment | 5–40 °C; humidity < 85 % |
| Power supply | USB-C 5 V 2.1 A, BC 2.1 protocol |
| Battery capacity | 8,000 mAh |
| Dimensions | 246 × 59.4 × 84 mm |
| Weight | 590 g |
| No. | Parameter | Method | Measuring range |
|---|---|---|---|
| 1 | Ammonia nitrogen | Nessler's reagent spectrophotometry | 0.05–200 mg/L |
| 2 | Ammonia nitrogen | Salicylic acid spectrophotometry | 0.025–25 mg/L |
| 3 | COD | Rapid digestion spectrophotometry | 10–15,000 mg/L |
| 4 | Total nitrogen | Chromotropic acid spectrophotometry | 0.5–200 mg/L |
| 5 | Total phosphorus | Ammonium molybdate / vanadomolybdophosphoric acid spectrophotometry | 0.02–30 mg/L |
| 6 | Phosphate | Ammonium molybdate / vanadomolybdophosphoric acid spectrophotometry | 0.03–80 mg/L |
| 7 | Nitrate | Chromotropic acid spectrophotometry | 0.1–100 mg/L |
| 8 | Nitrate nitrogen | Chromotropic acid spectrophotometry | 0.1–100 mg/L |
| 9 | Acidic permanganate index | Spectrophotometry | 0.1–25 mg/L |
| 10 | Anionic surfactants | Methylene blue spectrophotometry | 0.01–5 mg/L |
| 11 | Fluoride | Fluoride reagent spectrophotometry | 0.01–2 mg/L |
| 12 | Iron | 1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 13 | Total iron | 1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 14 | Copper | 2,9-dimethyl-1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 15 | Total copper | 2,9-dimethyl-1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 16 | Aluminium | Chrome azurol S spectrophotometry | 0.005–0.5 mg/L |
| 17 | Zinc | Zincon spectrophotometry | 0.05–3 mg/L |
| 18 | Manganese | Formaldoxime spectrophotometry | 0.01–5 mg/L |
| 19 | Total manganese | Formaldoxime spectrophotometry | 0.01–5 mg/L |
| 20 | Hexavalent chromium | Diphenylcarbazide spectrophotometry | 0.005–1 mg/L |
| 21 | Total chromium | Permanganate oxidation–diphenylcarbazide spectrophotometry | 0.005–1 mg/L |
| 22 | Arsenic | Silver diethyldithiocarbamate spectrophotometry | 0.01–0.5 mg/L |
| 23 | Mercury | Dithizone spectrophotometry | 0.005–0.1 mg/L |
| 24 | Total mercury | Dithizone spectrophotometry | 0.005–0.1 mg/L |
| 25 | Nickel | Dimethylglyoxime spectrophotometry | 0.02–5 mg/L |
| 26 | Total nickel | Dimethylglyoxime spectrophotometry | 0.02–5 mg/L |
| 27 | Free chlorine | DPD spectrophotometry | 0.01–30 mg/L |
| 28 | Total chlorine | DPD spectrophotometry | 0.01–30 mg/L |
| 29 | Chlorine dioxide | DPD spectrophotometry | 0.04–20 mg/L |
| 30 | Available chlorine | Iodometric method | 0.2–300 mg/L (water sample); 0.1–60 % (disinfectant) |
| 31 | Ozone | Indigo disulfonate spectrophotometry | 0.02–10 mg/L |
| 32 | Dissolved oxygen | Iodometric method | 0.1–12 mg/L |
| 33 | pH | Acid-base indicator colour development | 5.0–9.0 |
| 34 | Urea | Diacetyl monoxime spectrophotometry | 0.05–10 mg/L |
| 35 | Cyanuric acid | Turbidimetric method | 3–250 mg/L |
| 36 | Chlorite | Spectrophotometry | 0.05–2.5 mg/L |
| 37 | Bromate | Spectrophotometry | 0.004–0.05 mg/L |
| 38 | Water-soluble chromium in cement | Diphenylcarbazide spectrophotometry | 0.2–50 mg/kg |
| 39 | Volatile fatty acids | Ferric reagent colorimetry | 0.5–60 mmol/L |
| 40 | Chloride | Mercuric thiocyanate spectrophotometry | 1–500 mg/L |
| 41 | Sulfide | Methylene blue spectrophotometry | 0.05–2 mg/L |
| 42 | Sulfate | Barium chromate spectrophotometry | 5–200 mg/L |
| 43 | Fluoride | Fluoride reagent spectrophotometry | 0.01–2 mg/L |
| 44 | Nitrite | N-(1-naphthyl)ethylenediamine spectrophotometry | 0.005–0.25 mg/L |
| 45 | Nitrite nitrogen | N-(1-naphthyl)ethylenediamine spectrophotometry | 0.005–0.25 mg/L |
| 46 | Total hardness | — | 4–1,000 mg/L |
| 47 | Turbidity | Turbidimetric spectrophotometry | 0–2,000 NTU |
| 48 | Suspended solids | Turbidity-based correlation | 1 NTU = k × 1 mg/L |
| 49 | Colour | Platinum-cobalt colorimetry | 0–500 Hazen |
Products
Services
About
Contact
Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.
008619053605658

