Portable Multi-parameter Water Quality Analyzer measures COD, ammonia nitrogen, total phosphorus, total nitrogen and heavy metals with digestion and detection integrated in a portable case. Widely used for field water quality testing....
The portable multi-parameter water quality analyser adopts a high-strength PVC engineering plastic carrying case with an integrated digestion-and-measurement design. The digestion module offers dual temperature zones, while the measuring section supports both 360° rotating test-tube colorimetry and cuvette colorimetry. It runs on an Android smart operating system with an 8-inch HD LCD touch screen, fibre-optic detection technology, an imported light source and a built-in large-capacity lithium battery. The instrument offers stable performance, accurate measurement, a wide measuring range, powerful functions and simple operation.
The instrument is intended for the determination of multiple water pollutants in domestic sewage, industrial wastewater, groundwater and surface water. It is used for water quality analysis in testing laboratories, municipal authorities, wastewater treatment plants, environmental monitoring stations, universities and research institutes, power plants, centres for disease control, paper making and electroplating plants, aquaculture, biopharmaceutical production, petrochemicals, coal, metallurgy, textiles and the food industry.
Spectrophotometric module
Routine water quality parameters: COD, ammonia nitrogen, total nitrogen, total phosphorus, phosphate, nitrate nitrogen, nitrite nitrogen, permanganate index, turbidity, colour, suspended solids, dissolved oxygen and pH.
Disinfection parameters: free chlorine, total chlorine, chlorine dioxide, available chlorine, chlorite and bromate.
Heavy metals: copper, total copper, hexavalent chromium, total chromium, zinc, total zinc, iron, total iron, nickel, total nickel, manganese, total manganese, cadmium, lead, aluminium, arsenic, tin, mercury/total mercury, cobalt and titanium.
Other parameters: sulfate, fluoride, sulfide, cyanide, total cyanide, volatile phenol, aniline, formaldehyde, hydrogen peroxide, silicon dioxide, urea, chloride, anionic surfactants, cyanuric acid, ozone, total hardness and total alkalinity.
pH, ORP, dissolved oxygen (fluorescence), residual chlorine (constant-potential), conductivity, salinity, ozone, turbidity, hardness, suspended solids, sludge concentration, COD, ammonia nitrogen, chlorophyll, blue-green algae, oil-in-water and CDOM (coloured dissolved organic matter) sensors — several dozen types in total.
1. Android 7.1.1 smart operating system for a smoother interactive experience, faster response and greater stability.
2. Dual colorimetric system supporting both pre-made test tubes and cuvettes.
3. The tube measuring channel uses a 360° precision rotating mechanism, guaranteeing accuracy and improving stability tenfold.
4. Built-in dual-temperature-zone, 8-position digester with independent left and right zone control for rapid COD, total phosphorus and total nitrogen digestion.
5. Portable all-in-one design with a large-capacity lithium battery: digestion and measurement can both be carried out in the field with a single instrument.
6. Built-in thermal printer supporting automatic and batch printing, freely selectable and editable print content, and QR-code printing.
7. Wi-Fi, 4G and RJ45 wired network connectivity for uploading data.
8. Data cloud platform that receives measurement data for online storage and short- and long-term trend analysis.
9. Users can build their own standard curves, with custom calibration of both coefficient curves and sample curves.
10. Built-in instructional videos let users watch the procedure while operating the instrument, making it easier to learn.
11. Detection items can be customised on request.
12. Factory-prepared reagents are supplied: no repeated pipetting or concentrated sulfuric acid preparation is needed — simply add the water sample to the tube.
13. Favourite parameters can be pinned to the top of the item list, avoiding repeated searching.
14. GPS positioning displays the longitude, latitude and landmark of the sampling point in real time; the coordinates are saved with the data and can be uploaded to the cloud platform.
| Colorimetric method | Pre-made 16 mm test tubes; cuvettes up to 50 mm |
| Operating system | Android smart operating system |
| Display | 8-inch HD touch screen, 1024 × 768 |
| Indication error | ≤ ±5 % |
| Repeatability | < 0.5 % |
| Stability | < 0.5 % |
| Resolution | 0.001 |
| Optical stability | ≤ ±0.001 Abs/20 min (100,000 h lamp life) |
| Automatic calibration | Supported |
| Printing | Built-in micro thermal printer |
| Instructional videos | Step-by-step demonstrations for ≥ 4 items |
| Data upload | Wireless upload to the cloud platform; real-time viewing on mobile phones and PCs |
| Battery | 48 V 8 Ah lithium battery |
| Runtime at full charge | More than 6 h of continuous operation with digestion and measurement (COD as example) |
| Data transmission | USB, RJ45, Wi-Fi |
| Digestion positions | 8, with independent dual-zone control |
| Heating rate | Room temperature to 165 °C within 10 min |
| Digestion temperature | Room temperature to 200 °C, adjustable |
| Digestion volume | 0–10 mL |
| Temperature control | Intelligent PID |
| Temperature accuracy | ±0.5 °C |
| Preset digestion programs | COD, total phosphorus, total nitrogen, permanganate index, sulfate, formaldehyde |
| Custom digestion programs | 4 |
| Data storage | 10 million data sets, freely recallable |
| Power supply | DC 48 V 2 A |
| Dimensions | 430 × 350 × 200 mm |
| Weight | 11 kg |
| No. | Parameter | Method | Measuring range |
|---|---|---|---|
| 1 | Ammonia nitrogen | Nessler's reagent spectrophotometry | 0.05–200 mg/L |
| 2 | Ammonia nitrogen | Salicylic acid spectrophotometry | 0.025–25 mg/L |
| 3 | COD | Rapid digestion spectrophotometry | 10–15,000 mg/L |
| 4 | Total nitrogen | Chromotropic acid spectrophotometry | 0.5–200 mg/L |
| 5 | Total phosphorus | Ammonium molybdate / vanadomolybdophosphoric acid spectrophotometry | 0.02–30 mg/L |
| 6 | Phosphate | Ammonium molybdate / vanadomolybdophosphoric acid spectrophotometry | 0.03–80 mg/L |
| 7 | Nitrate | Chromotropic acid spectrophotometry | 0.1–100 mg/L |
| 8 | Nitrate nitrogen | Chromotropic acid spectrophotometry | 0.1–100 mg/L |
| 9 | Acidic permanganate index | Spectrophotometry | 0.1–25 mg/L |
| 10 | Anionic surfactants | Methylene blue spectrophotometry | 0.01–5 mg/L |
| 11 | Fluoride | Fluoride reagent spectrophotometry | 0.01–2 mg/L |
| 12 | Iron | 1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 13 | Total iron | 1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 14 | Copper | 2,9-dimethyl-1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 15 | Total copper | 2,9-dimethyl-1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 16 | Aluminium | Chrome azurol S spectrophotometry | 0.005–0.5 mg/L |
| 17 | Zinc | Zincon spectrophotometry | 0.05–3 mg/L |
| 18 | Manganese | Formaldoxime spectrophotometry | 0.01–5 mg/L |
| 19 | Total manganese | Formaldoxime spectrophotometry | 0.01–5 mg/L |
| 20 | Hexavalent chromium | Diphenylcarbazide spectrophotometry | 0.005–1 mg/L |
| 21 | Total chromium | Permanganate oxidation–diphenylcarbazide spectrophotometry | 0.005–1 mg/L |
| 22 | Arsenic | Silver diethyldithiocarbamate spectrophotometry | 0.01–0.5 mg/L |
| 23 | Mercury | Dithizone spectrophotometry | 0.005–0.1 mg/L |
| 24 | Total mercury | Dithizone spectrophotometry | 0.005–0.1 mg/L |
| 25 | Nickel | Dimethylglyoxime spectrophotometry | 0.02–5 mg/L |
| 26 | Total nickel | Dimethylglyoxime spectrophotometry | 0.02–5 mg/L |
| 27 | Free chlorine | DPD spectrophotometry | 0.01–30 mg/L |
| 28 | Total chlorine | DPD spectrophotometry | 0.01–30 mg/L |
| 29 | Chlorine dioxide | DPD spectrophotometry | 0.04–20 mg/L |
| 30 | Available chlorine | Iodometric method | 0.2–300 mg/L (water sample); 0.1–60 % (disinfectant) |
| 31 | Ozone | Indigo disulfonate spectrophotometry | 0.02–10 mg/L |
| 32 | Dissolved oxygen | Iodometric method | 0.1–12 mg/L |
| 33 | pH | Acid-base indicator colour development | 5.0–9.0 |
| 34 | Urea | Diacetyl monoxime spectrophotometry | 0.05–10 mg/L |
| 35 | Cyanuric acid | Turbidimetric method | 3–250 mg/L |
| 36 | Chlorite | Spectrophotometry | 0.05–2.5 mg/L |
| 37 | Bromate | Spectrophotometry | 0.004–0.05 mg/L |
| 38 | Water-soluble chromium in cement | Diphenylcarbazide spectrophotometry | 0.2–50 mg/kg |
| 39 | Volatile fatty acids | Ferric reagent colorimetry | 0.5–60 mmol/L |
| 40 | Chloride | Mercuric thiocyanate spectrophotometry | 1–500 mg/L |
| 41 | Sulfide | Methylene blue spectrophotometry | 0.05–2 mg/L |
| 42 | Sulfate | Barium chromate spectrophotometry | 5–200 mg/L |
| 43 | Fluoride | Fluoride reagent spectrophotometry | 0.01–2 mg/L |
| 44 | Nitrite | N-(1-naphthyl)ethylenediamine spectrophotometry | 0.005–0.25 mg/L |
| 45 | Nitrite nitrogen | N-(1-naphthyl)ethylenediamine spectrophotometry | 0.005–0.25 mg/L |
| 46 | Total hardness | — | 4–1,000 mg/L |
| 47 | Turbidity | Turbidimetric spectrophotometry | 0.2–300 NTU |
| 48 | Suspended solids | Turbidity-based correlation | 1 NTU = k × 1 mg/L |
| 49 | Colour | Platinum-cobalt colorimetry | 0–500 Hazen |