Products

Model:
HD-BL100
Introduction:
Portable Water Quality Analyzer (Portable Multi-parameter Water Quality Analyzer) measures multiple pollution indicators in water by the multi-wavelength spectrophotometric method with integrated digestion. Widely used for industrial wastewater and municipal sewage....
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
This instrument is an integrated portable water quality analyser based on multi-wavelength spectrophotometry. Digestion, measurement and data transmission are combined in one unit; a built-in multi-wavelength optical system and preset standard curves, together with dedicated pre-prepared reagents, allow dozens of water quality parameters to be determined quickly and accurately at the touch of a button. The design fully meets the requirements of complex on-site water analysis: a large-capacity battery, digestion unit and thermal printer are built in for independent field operation, while 4G/Wi-Fi, GPS and cloud platform functions close the loop from on-site testing to data traceability management.
The instrument performs quantitative water quality analysis on the principle of spectrophotometry. An LED light source system is used and the optimum analytical wavelength for each parameter is fixed in advance according to the national standard method, ensuring specificity and accuracy. The user applies the supplied pre-prepared reagent; after colour development the test tube or measuring bottle is placed in the measuring compartment, the absorbance at the specific wavelength is measured precisely and the concentration is calculated automatically from the stored standard curve according to the Lambert-Beer law.
Industrial wastewater: influent, process units and outfall monitoring at wastewater treatment stations in electroplating, printing and dyeing, pharmaceutical and food processing plants.
Municipal sewage: influent, biological units, effluent and reuse water inspection at wastewater treatment plants.
Environmental water bodies: rivers, lakes, reservoirs and wetlands, groundwater monitoring wells and private water sources — routine monitoring and pollution screening.
Drinking water safety: drinking water source protection areas, backup sources and rural centralised water supply facilities.
Enforcement and emergency response: surprise sampling at enterprise outfalls, park outfall patrols, on-site screening of sudden water pollution incidents and pollution plume tracking.
Research and teaching: water quality research, process optimisation and on-site testing and data collection for teaching experiments in universities and research institutes.
1. Android 7.1.1 smart operating system for a smoother interactive experience, faster response and greater stability.
2. Turbidity bottle and test-tube measuring channels, switchable with a tube holder.
3. Built-in 6-position digester and 6-position cooling fan with independent control.
4. Measurement, digestion and cooling can be carried out simultaneously, greatly improving efficiency.
5. Detection items can be customised on request.
6. Factory-prepared reagents are supplied: simply add the water sample to the tube.
7. Favourite parameters can be pinned to the top of the item list, avoiding repeated searching.
8. Portable all-in-one design with a large-capacity lithium battery: digestion and measurement can both be carried out in the field with a single instrument.
9. Built-in thermal printer supporting automatic and batch printing, freely selectable and editable print content, and QR-code printing.
10. Built-in instructional videos let users watch the procedure while operating the instrument.
11. Wi-Fi and 4G modules for wireless data upload.
12. Data cloud platform for online storage and short- and long-term trend analysis.
13. GPS positioning displays the longitude, latitude and landmark of the sampling point in real time; the coordinates are saved with the data and can be uploaded to the cloud platform.
| Light source wavelengths | 420, 470, 520, 560, 620, 700, 860 nm |
| Indication error (RE) | Not exceeding ±10 %; not exceeding ±5 % for some items |
| Repeatability (RSD) | ≤ 3 % |
| Optical stability | ≤ 0.002 Abs/30 min |
| Absorbance resolution | 0.001 Abs |
| Absorbance range | −3.0 to 3.0 Abs |
| Measuring method | Transmission + scattering |
| Light source | LED |
| Detection items | See the appendix; reagents are optional |
| Operating system | Android 7.1.1 smart operating system |
| Display | 8-inch HD colour LCD touch screen |
| Network interface | Wi-Fi, 4G |
| Interface language | Chinese / English (factory option) |
| Colorimetric method | Test tube, measuring bottle |
| Printer | Thermal line printer |
| Communication interface | USB 2.0 |
| Power supply | AC 220 V; large-capacity rechargeable lithium battery supplied as standard |
| Data export format | |
| Cloud platform | Built-in regulatory platform; results are transmitted directly to the environmental safety supervision platform once networked |
| Dimensions | 430 × 350 × 190 mm |
| Weight | 8.3 kg |
| Ambient temperature | 5–40 °C |
| Ambient humidity | < 85 % RH (non-condensing) |
| Power consumption | 50 W (digestion off), 150 W (maximum) |
| No. | Parameter | Method | Measuring range |
|---|---|---|---|
| 1 | Ammonia nitrogen | Nessler's reagent spectrophotometry | 0.05–200 mg/L |
| 2 | Ammonia nitrogen | Salicylic acid spectrophotometry | 0.025–25 mg/L |
| 3 | COD | Rapid digestion spectrophotometry | 10–15,000 mg/L |
| 4 | Total nitrogen | Chromotropic acid spectrophotometry | 0.5–200 mg/L |
| 5 | Total phosphorus | Ammonium molybdate / vanadomolybdophosphoric acid spectrophotometry | 0.02–30 mg/L |
| 6 | Phosphate | Ammonium molybdate / vanadomolybdophosphoric acid spectrophotometry | 0.03–80 mg/L |
| 7 | Nitrate | Chromotropic acid spectrophotometry | 0.1–100 mg/L |
| 8 | Nitrate nitrogen | Chromotropic acid spectrophotometry | 0.1–100 mg/L |
| 9 | Acidic permanganate index | Spectrophotometry | 0.1–25 mg/L |
| 10 | Anionic surfactants | Methylene blue spectrophotometry | 0.01–5 mg/L |
| 11 | Fluoride | Fluoride reagent spectrophotometry | 0.01–2 mg/L |
| 12 | Iron | 1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 13 | Total iron | 1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 14 | Copper | 2,9-dimethyl-1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 15 | Total copper | 2,9-dimethyl-1,10-phenanthroline spectrophotometry | 0.02–5 mg/L |
| 16 | Aluminium | Chrome azurol S spectrophotometry | 0.005–0.5 mg/L |
| 17 | Zinc | Zincon spectrophotometry | 0.05–3 mg/L |
| 18 | Manganese | Formaldoxime spectrophotometry | 0.01–5 mg/L |
| 19 | Total manganese | Formaldoxime spectrophotometry | 0.01–5 mg/L |
| 20 | Hexavalent chromium | Diphenylcarbazide spectrophotometry | 0.005–1 mg/L |
| 21 | Total chromium | Permanganate oxidation–diphenylcarbazide spectrophotometry | 0.005–1 mg/L |
| 22 | Arsenic | Silver diethyldithiocarbamate spectrophotometry | 0.01–0.5 mg/L |
| 23 | Mercury | Dithizone spectrophotometry | 0.005–0.1 mg/L |
| 24 | Total mercury | Dithizone spectrophotometry | 0.005–0.1 mg/L |
| 25 | Nickel | Dimethylglyoxime spectrophotometry | 0.02–5 mg/L |
| 26 | Total nickel | Dimethylglyoxime spectrophotometry | 0.02–5 mg/L |
| 27 | Free chlorine | DPD spectrophotometry | 0.01–30 mg/L |
| 28 | Total chlorine | DPD spectrophotometry | 0.01–30 mg/L |
| 29 | Chlorine dioxide | DPD spectrophotometry | 0.04–20 mg/L |
| 30 | Available chlorine | Iodometric method | 0.2–300 mg/L (water sample); 0.1–60 % (disinfectant) |
| 31 | Ozone | Indigo disulfonate spectrophotometry | 0.02–10 mg/L |
| 32 | Dissolved oxygen | Iodometric method | 0.1–12 mg/L |
| 33 | pH | Acid-base indicator colour development | 5.0–9.0 |
| 34 | Urea | Diacetyl monoxime spectrophotometry | 0.05–10 mg/L |
| 35 | Cyanuric acid | Turbidimetric method | 3–250 mg/L |
| 36 | Chlorite | Spectrophotometry | 0.05–2.5 mg/L |
| 37 | Bromate | Spectrophotometry | 0.004–0.05 mg/L |
| 38 | Water-soluble chromium in cement | Diphenylcarbazide spectrophotometry | 0.2–50 mg/kg |
| 39 | Volatile fatty acids | Ferric reagent colorimetry | 0.5–60 mmol/L |
| 40 | Chloride | Mercuric thiocyanate spectrophotometry | 1–500 mg/L |
| 41 | Sulfide | Methylene blue spectrophotometry | 0.05–2 mg/L |
| 42 | Sulfate | Barium chromate spectrophotometry | 5–200 mg/L |
| 43 | Fluoride | Fluoride reagent spectrophotometry | 0.01–2 mg/L |
| 44 | Nitrite | N-(1-naphthyl)ethylenediamine spectrophotometry | 0.005–0.25 mg/L |
| 45 | Nitrite nitrogen | N-(1-naphthyl)ethylenediamine spectrophotometry | 0.005–0.25 mg/L |
| 46 | Total hardness | — | 4–1,000 mg/L |
| 47 | Turbidity | Turbidimetric spectrophotometry | 0–2,000 NTU |
| 48 | Suspended solids | Turbidity-based correlation | 1 NTU = k × 1 mg/L |
| 49 | Colour | Platinum-cobalt colorimetry | 0–500 Hazen |
Products
Services
About
Contact
Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.
008619053605658