
Rapid Detector for Drug Residues in Aquatic Products
manufacturer:Shandong Horde Electronic Technology Co., Ltd.
Introduction:The manufacturer of Rapid Detector for Drug Residues in Aquatic Products「Horde Electronic」 has mastered the research and development technology of Rapid Detector for Drug Residues in Aquatic Products, with more than 10 years of experience in manufacturing Rapid Detector for Drug Residues in Aquatic Products. The quality is reliable, the detection accuracy is high, and the price competitive advantage of the source manufacturer is obvious. Welcome to call for more information.
Update time:2025-06-14
- Contact: Contact Information
- Phone:008618863942319
Product Recommendation
Product Details
1. Application scope:
The rapid drug residue detector for aquatic products is suitable for the qualitative and quantitative detection of malachite green, furazolidone (AOZ), furaltadone (AMOZ), nitrofurantoin (AHD), nitrofurazone (SEM), chloramphenicol, sulfonamides, quinolones, and enrofloxacin in aquatic products such as fish and shrimp.
2. Product overview:
Malachite green, furazolidone (AOZ), furaltadone (AMOZ), nitrofurantoin (AHD), nitrofurazone (SEM), chloramphenicol, sulfonamides, quinolones, and enrofloxacin are highly effective broad-spectrum antibiotics, commonly used in the treatment of various infectious diseases in animals, and have a strong inhibitory effect on a variety of pathogens. They have been widely used in aquatic products and livestock and poultry farming, but also brought about serious problems of chloramphenicol residues in aquatic products and livestock and poultry. Chloramphenicol has serious toxic side effects, which can inhibit the hematopoietic function of human bone marrow, cause human aplastic anemia, granulocytopenia, gray syndrome of neonates and premature infants, and low concentrations of drug residues can also induce drug resistance of pathogenic bacteria. Therefore, chloramphenicol residues in animal food pose a huge threat to human health. This product uses the principle of immunochromatography technology to qualitatively detect chloramphenicol residues in samples such as fish, shrimp, chicken, pig, and cattle. It has the characteristics of simple operation, short detection time, and can be directly interpreted by the naked eye. It is suitable for on-site rapid detection of various enterprises and testing institutions.
3. Product use:
Rapid detection instrument for drug residues in aquatic products is widely used in the Food and Drug Administration, health supervision departments, colleges and universities, agricultural departments, commercial system farms, slaughterhouses, food and meat product deep processing enterprises, animal husbandry and veterinary medicine, inspection and quarantine departments, food production enterprises, agricultural and sideline products wholesale markets, agricultural production bases, supermarkets, restaurants, canteens and other units and departments to monitor and use unsafe indicators in food.
4. Product performance:
1. Android smart operating system, adopts more efficient and user-friendly operation. The instrument has network cable connection, wifi network upload, GPRS wireless remote transmission function, and fast data upload.
2. High degree of intelligence, the instrument has self-test function: it has power-on self-test and zero adjustment function, and has automatic detection repeatability function.
3. A new generation of high-speed thermal printer, which can automatically print the test report and QR code after the test is completed.
4. The instrument has a supervision platform. Data can be uploaded to the local area network and the Internet, and the test results are directly transmitted to the food safety supervision platform. Carry out regional food safety supervision and big data analysis and processing and data statistics, detect the long-term and short-term dynamics of regional food safety, and achieve food safety problem estimation and early warning.
6. Integrated portable rapid testing equipment, meet the needs of on-site and mobile testing, can realize the detection of all test items under the same software, and can intuitively display the test results through the same window.
7. Colloidal gold module detection method: track-type automatic transmission scanning, automatically exit the test card after the test is completed.
8. CT line automatic recognition, no manual adjustment required.
9. The instrument has a variety of sample menu libraries, which can flexibly select test samples, and different test channels can detect different sample items at the same time.
10. Sample processing is simple and labor-saving, and the overall operation is fast, safe and convenient.
11. The instrument has its own protection function, and the user name and password can be set to prevent non-staff operations.
12. High sensitivity, high detection accuracy, high repeatability accuracy, scanning high-precision optical sensor.
13. Built-in powerful database, you can directly select sample name, detection indicators, inspection unit and other information on the instrument, or directly edit and enter sample name, detection indicators, inspection unit and other information on the instrument and save it into the sample database.
14. The instrument has the functions of recalibration, locking, and restoring factory settings.
15. Support U disk storage. The result judgment line can be modified, the control value calibration value can be saved, and the power is off without losing data.
16. Compatible with all colloidal gold cards on the market, the use of consumables is not restricted, and the user experience is greatly enhanced.
5. Main parameters:
1. The main control chip adopts ARM Cortex-A7, RK3288/4 core processor, with a main frequency of 1.88Ghz, faster operation speed and stronger stability.
2. Display mode: 7-inch LCD touch screen display, humanized Chinese operation interface, intuitive and simple reading.
3. AC and DC dual-purpose, DC 12V power supply, can be connected to the vehicle power supply, and can be equipped with 6ah large-capacity rechargeable lithium battery, which is convenient for outdoor flow testing.
5. Automatic adjustment and calibration of light source brightness
6. Intelligent constant current voltage regulation, automatic calibration of light intensity, and no temperature drift of light source for long-term continuous operation.
7. Built-in new national limit standards, on-site comparison with the measured results, and continuous update of standards.
9. Uninterrupted sampling and continuous detection
8. Sample numbers are automatically accumulated.
10. The detection items can be expanded.
11. The test results can be printed and uploaded in batches.
12. The test results are Excel tables, which can be copied by connecting to a computer.
13. Storage capacity of 200,000 test results
14. Standard USB interface, no driver installation required.
15. Firmware upgradeable
6. Chloramphenicol detection method steps
How to use colloidal gold card:
[Sample processing]
1. Take more than 100g of representative samples and crush them, weigh 3.0g of evenly crushed samples and add them to a 15mL centrifuge tube.
2. Accurately add 5mL of reagent A to the 15mL centrifuge tube, seal the bottle cap tightly, and mix the sample up and down for 3min.
3. Centrifuge the above sample at 4000rpm for 3min, take 3mL of supernatant in a 10mL centrifuge tube, and blow dry under nitrogen (air) in a 50~60℃ water bath.
4. Add 0.5mL of reagent B and 0.3mL of diluent, mix well, and let stand until the liquid is clearly stratified (or centrifuged at 4000rpm for 3min), and the lower layer of liquid is to be tested.
【Testing steps】
1. Before use, restore the test card and the sample solution to room temperature, take out the test card from the packaging bag, and lay the test card flat.
2. Use a disposable dropper to add 5 drops of the test solution to the sample well.
3. Start timing after adding the sample, and observe the results after 5-8 minutes. After 8 minutes, the judgment is invalid.
4. Start timing after adding the sample, operate the machine to pop up and slide within 5-8 minutes, put in the colloidal gold card to read the value, record the results, and print out the test report
Note: The dropper for adding the sample must be used once to prevent cross contamination.
Product's Website:http://en.huoerd.com/kssjcy/1111.html