EN
Position:Home>Products>Food Rapid Test>Veterinary Drug Residue Detector>Laboratory>Veterinary Drug Residue Detector

Products

Veterinary Drug Residue Detector

Model:

HD-SY02

Introduction:

Gold Immunochromatography Reader (Colloidal Gold Detector) is a multi-channel optical reader for gold immunochromatographic strips, reading multiple samples simultaneously. Widely used for medical diagnosis, food safety and high-throughput screening....

  • Image and Text Display
  • Technical Specifications
  • Product video

I. Product Overview

This veterinary-drug residue detector is used for the on-site rapid screening, qualitative and quantitative detection of veterinary-drug residues in animal-derived foods (meat, eggs, milk, aquatic products, honey, etc.) and their products, including antibiotics, hormones, anthelmintics, sedatives and beta-agonists. It is essential for food-safety assurance, consumer-health protection, international trade and animal-derived product quality, and is widely used in farms/slaughterhouses, food-processing enterprises, market regulators (food-drug administration, agriculture ministry, etc.), third-party testing agencies, wholesale markets/supermarkets and research institutes.

II. Detection Items

Lean-meat-powder hormones: clenbuterol, salbutamol, ractopamine, diethylstilbestrol, olaquindox, etc.

Antibiotic residues: tetracyclines, nitrofurans, sulfonamides, beta-agonists, quinolones, thiamphenicol, florfenicol, amantadine, tilmicosin, gentamicin, lincomycin, streptomycin, enrofloxacin, ciprofloxacin, cefradine, penicillin, amoxicillin, etc.

Aquatic-product safety: malachite green, chloramphenicol, nitrofurantoin, nitrofurazone, furaltadone, furazolidone, etc.

Drug residues in eggs: chloramphenicol, tetracycline, sulfonamides, quinolones, nitrofurazone, furaltadone, nitrofurantoin, furazolidone, florfenicol, amoxicillin, cephalexin, erythromycin, streptomycin, etc.

Animal diseases: avian influenza, Newcastle disease, FMDV (cattle/sheep), bovine tuberculosis, echinococcosis, brucellosis, PPR, PRRSV, CSFV, pseudorabies, parvovirus, PCV, canine parvovirus, canine distemper, rabies, etc.

III. Instrument Features

Android touch system with a large HD screen; friendly interface, smooth operation, no external device required.

6 channels can simultaneously detect different items, greatly improving efficiency for batch-sample processing.

8 GB large-capacity storage; flexible query, preview and deletion by date, and generation of diversified professional reports.

Built-in thermal printer prints standard reports on site, improving work efficiency.

Real-time self-diagnosis of key components ensures long-term stable operation.

High-speed wired/wireless network and Bluetooth build a complete data-monitoring platform for real-time upload, remote query, statistical analysis and regulatory coordination.

Rich interface design easily connects to PC, U-disk, network and host system, supporting U-disk export.

Incubation module provides a precise temperature environment for specific test strips.

Streamlined structure, compact and lightweight, balancing lab durability and testing needs.

Insertion check: detection cannot start unless the card is inserted into the channel.

Built-in quality-control function supporting device calibration and inspection.

Detection modes: incubation detection and instant detection (re-check of data).

Detection curve: verifies reagent cards to prevent misjudgment.

Results show test item, substance concentration, testing unit, inspected unit, inspector, test time and detection limit on the touch screen, and can be printed via the built-in printer.

Project management: supports item expansion.

Interface settings: editable title and footer to flexibly display instrument information.

A4 printing via an external Wi-Fi printer; supports electronic seal and signature.

Supports host-computer operation of the instrument.

Supports remote OTA upgrade.

IV. Technical Parameters

ParameterSpecification
Screen7-inch capacitive touch screen, 1024x600 resolution; internal storage 1+8 GB
Operating systemAndroid 7.1
Detection methodreflective photoelectric detection
Compatible card70 mm x 20 mm
LanguageChinese / English
Storage count100,000+
Accuracyerror <= 5%
StabilitySW (fluctuation coefficient) <= 5%
RepeatabilityCV (coefficient of variation) <= 3%
Resolution0.001
Detection channel6-channel detection
Detection time< 5 s (single and multi-card); qualitative/semi-quantitative colloidal-gold detection
Data transmissionWi-Fi, Bluetooth, USB
Data processingdata aggregation, upload to supervision platform via communication port
Incubationchannel-incubation integrated; incubation temperature: room temp +5 C to 60 C
Printerthermal printer (paper 57x20 mm)
InterfacesUSB-A x2; USB-B x1; LAN x1; DC 5.5/2.5 mm
Powerinput AC 100-240V/1.3A 50Hz; output DC 12V/5A
Power consumption<= 60 W
Environmenttemperature 15-30 C; relative humidity <= 75%
Dimensions308 x 205 x 91 mm
Weightapprox. 2.7 kg
Package51 x 39 x 37.5 cm
The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top