EN
Position:Home>Products>Gas Detection>Mercury Vapor Analyzer>Mercury Vapor Analyzer

Products

Mercury Vapor Analyzer

Model:

HD-MV1

Introduction:

Mercury Vapor Analyzer measures mercury vapor accurately within 3 seconds using dual-beam UV absorption technology without saturation. Widely used for monitoring any site with mercury or mercury compounds in industry, labs and environmental testing....

  • Image and Text Display
  • Technical Specifications
  • Product video

Product Introduction

The Mercury Vapor Analyzer is a revolutionary instrument that can accurately detect hazardous mercury vapor in just 3 seconds. It uses a distinctive dual-beam UV absorption technology, capable of measuring high concentrations of mercury vapor without saturation. In addition, the instrument does not need to be reset between two readings, thereby reducing downtime. It is mainly used to monitor any environment where mercury (or mercury compounds) is generated, processed or stored, as well as applications where mercury vapor may pose a health hazard to operators. The measurement unit of mercury vapor is micrograms per cubic meter, expressed as µg/m³.

Typical Applications

  • Ambient air analysis.
  • Hazardous substance / emergency response.
  • Spectral response.
  • Industrial hygiene and worker safety.
  • Gold mining.
  • Regulatory compliance.
  • Detection and cleaning.
  • Scrubber efficiency monitoring.
  • Mercury exclusion testing.
  • Lamps and mercury switches.
  • Equipment monitoring.

Compliant Standards

  • Complies with the mercury vapor detection requirements of GBZ 2.1-2019 Occupational Exposure Limits for Hazardous Agents in the Workplace
  • Complies with HJ/T 397-2007 Technical Specifications for Emission Monitoring of Stationary Pollution Sources
  • Complies with ISO 17733:2004 Indoor air - Determination of inorganic chemical substances - Determination of mercury vapor
  • Complies with the methodological standards of USEPA 7473 / NIOSH 6009
  • Meets the regulatory requirements for mercury vapor detection in applications such as environmental protection, occupational health and safety testing

Product Features

  • Dual-beam UV absorption detector: one beam is the measuring light and one beam is the reference light, which can automatically deduct light source drift and background interference, ensuring the stability and high accuracy of long-term measurement.
  • Closed-loop constant-intensity cold cathode mercury lamp light source: closed-loop control technology is adopted to automatically adjust the mercury lamp intensity in real time, effectively compensating for light source drift at the initial stage of startup and during long-term operation; no preheating is required, and stable testing can be carried out immediately after startup.
  • High selectivity: responds only to the strong absorption peak of mercury atoms at 253.65 nm, and is not interfered with by other common gases.
  • Real-time detection: 3-second fast response, displaying the concentration instantly, convenient for on-site real-time monitoring.
  • Ultra-low detection limit: as low as 0.01 µg/m³, meeting the needs of trace mercury monitoring.
  • Real-time curve: the main interface displays a real-time data curve, allowing the real-time change trend of mercury concentration to be viewed.
  • Large-screen display: built-in 4-inch high-definition color LCD screen, intuitive and convenient to operate.
  • Automatic calibration: built-in zero and span calibration functions, simplifying operation and improving measurement reliability.
  • Sound and light alarm: users can select the alarm threshold themselves; when the limit is exceeded, an automatic prompt is given together with a sound and light warning to ensure personnel safety.
  • Portable design: small size and light weight, can be held with one hand, suitable for rapid on-site detection and mobile monitoring.
  • With WiFi networking function, the device software supports remote upgrade and maintenance.

Technical Specifications

FunctionQuantitative detection of mercury (Hg) concentration in the environment below and above the acceptable exposure limit
DetectorDual-beam UV absorption detector
Detection range0.1-200 µg/m³ and 1-2000 µg/m³ (user selectable)
Resolution0.01 µg/m³
Detection limit0.01 µg/m³
Accuracy±5 µg of reading or ±10%
Repeatability±5% FSD (at 200 µg/m³)
Response timeAbout 3 seconds
Photometric noise0.0001 Abs
Sampling frequency1 time/s, 2 times/s, 3 times/s and 5 times/s (freely selectable)
Alarm thresholds10 µg/m³, 20 µg/m³, 25 µg/m³, 50 µg/m³ and 100 µg/m³ (freely selectable)
Light sourceClosed-loop constant-intensity cold cathode mercury lamp
Display specification4-inch high-definition color LCD screen
Data outputUSB interface
Storage capacityMore than 10,000 records
Working temperature+10℃ to +50℃
Working humidity(0-95)%RH
Battery working time≥ 7 h
Lithium battery capacity12.6V 3000 mAh
Charging time≤ 1 h
Networking functionSupports WiFi networking and remote upgrade and maintenance of the device software
Working power supply220 VAC / 12.6 VDC
Power consumption≤ 5 W
Main unit weight≤ 2 kg
Overall dimensions264 × 132 × 158 mm
OperationNo preheating required; the instrument is connected to the filter and sampling tube, and after startup and the response time, the mercury vapor level in the environment is displayed in real time

Comparison with UK Ion MVI

Function / ParameterMV1UK Ion MVI
Display4-inch color LCD screen, real-time concentration curve displayMonochrome screen, displays values only
DetectorDual-beam UV absorption detectorDual-beam UV absorption module
Measurement range0.1-200 µg/m³ and 1-2000 µg/m³0.1-199.9 and 1-1999 µg/m³
Resolution0.01 µg/m³0.1 µg/m³
Detection limit0.01 µg/m³0.1 µg/m³ and 1 µg/m³
Accuracy±5 µg of reading or ±10%±5 µg of reading or ±10%
Repeatability±5% FSD±5% FSD
Response timeAbout 3 secondsAbout 3 seconds
Photometric noiseYesNot displayed
Sampling frequency1 time/s, 2 times/s, 3 times/s and 5 times/sNone
Alarm thresholds10 µg/m³, 20 µg/m³, 25 µg/m³, 50 µg/m³ and 100 µg/m³ (freely selectable)Factory preset 20 µg/m³, not changeable
Alarm promptSound and light alarmSound alarm
Data outputUSB portCan output only after adding a storage module
Storage capacityStandard configuration more than 10,000 recordsRequires a separate storage module, high cost
Battery working time≥ 7 hMore than 5.5 hours after full charge
Preheating requiredNo preheating requiredRequires brief preheating
Real-time curve displayYesNo
Calibration functionBuilt-in zero and span calibration functionsNone (calibration must be returned abroad, very high cost)
Supply / repairIn stock / easy and low-cost repair beyond warrantyLong lead time / repair must be sent back to UK at high cost
The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top