Halogen Moisture Analyzer measures moisture content by the thermogravimetric method using a high-precision balance and halogen heating. Widely used in food, pharmaceutical, chemical, agricultural and laboratory rapid moisture testing....

  • Image and Text Display
  • Technical Specifications
  • Product video

Product Introduction

The Halogen Moisture Analyzer adopts the thermogravimetric (loss-on-drying) principle. A high-precision weighing system works together with a halogen lamp heating system to continuously monitor mass changes during sample drying, automatically calculating moisture content, solid content, moisture regain rate and wet-weight rate. Equipped with a TFT color touch screen, the instrument supports multiple drying modes and stop modes, making it ideal for rapid moisture testing in both laboratories and on the production floor.

Applicable industries: pharmaceuticals, grain, feed, seeds, dehydrated vegetables, tobacco, chemical engineering, tea, food, meat, agriculture and forestry, papermaking, rubber, plastics, textiles, and more.

Product Features

(1) Ring-shaped halogen lamp heating delivers fast temperature rise, even heat distribution and high testing efficiency.

(2) High-precision weighing sensor ensures stable readings and excellent repeatability.

(3) 5-inch TFT color touch screen offers intuitive operation and clearly displayed results.

(4) One-key calibration and overload protection guarantee accurate weighing.

(5) Voice reminder and buzzer alarm functions make operation safe and convenient.

(6) Equipped with an RS232 communication interface for convenient data transmission and connection to external devices.

(7) Supports three drying modes - rapid, standard and gentle - to suit different sample characteristics.

(8) Supports three stop modes - automatic stop, timed stop and manual stop. The timed stop range is 1-99 minutes, and heating can be stopped manually at any time.

(9) Sample name, drying temperature, drying mode, stop mode and timing can all be set as parameters.

(10) Displays a real-time time-versus-moisture curve during testing for more intuitive and concise results.

(11) Comes with a stainless steel or aluminum sample pan - healthy, eco-friendly, corrosion-resistant and highly flame-retardant.

(12) Can display or output test results including moisture, solid content, wet-weight rate and moisture regain rate.

(13) Supports connection to an external thermal printer, which can print sample name, start time, initial weight, final weight, moisture content, solid content, wet-weight rate and moisture regain rate.

(14) Supports historical data storage of up to 1,000 test records.

(15) External weight calibration; a 50 g calibration weight is included as standard.

(16) Dual-handle flip lid and anti-scald heating tray for safer operation.

Technical Parameters

ModelB501B502B505B111B112B115B121B122B125S501S111S121S122S125
Maximum Capacity50g50g50g110g110g110g120g120g120g50g110g120g120g120g
Reading Accuracy0.001g0.002g0.005g0.001g0.002g0.005g0.001g0.002g0.005g0.001g0.001g0.001g0.002g0.005g
Moisture Readability0.01% / 0.02%Note
Display5-inch TFT color touch screen
Pan SizeΦ100mm (1 stainless steel pan + 4 disposable aluminum pans) / Φ100mm (2 stainless steel sample pans)
Dimensions390mm × 225mm × 205mm
Weight4.1 kg
Temperature Range40-180℃ / 40-200℃
History Storage1,000 records
Data ConnectionRS232 / None / RS232
Heating MethodHalogen lamp
Temperature SensorK-type thermocouple
Operating Ambient Temperature5-35℃
Temperature Setting Interval1℃
Moisture Measurement Range0.00% - 100.00%
Drying Remaining Range100.00% - 0.00%
Time Setting Range1-99 min
Calibration MethodExternal calibration
Power / Power Consumption220V±15% 50Hz, 400W
Weighing SensorDomestic sensor / German HBM sensor

Note: moisture readability 0.01% applies to B501/B111/B121/S501/S111/S121; 0.02% applies to B502/B112/B122; 0.01% applies to B505/B115/B125/S122; 0.02% applies to S125.

Standard Configuration and Usage Recommendations

1) Standard Configuration:

· Instrument main unit

· Power adapter

· Aluminum / stainless steel sample pan

· Pan removal tool

· 50 g calibration weight

· Tweezers

· User manual

· Certificate of conformity

· Warranty card

2) Usage Recommendations:

· It is recommended to spread the sample in a thin, even layer to improve drying efficiency and repeatability.

· For high-moisture samples, reduce the sample amount appropriately; for low-moisture samples, increase it appropriately.

· For liquid or paste samples, it is recommended to disperse the sample using glass-fiber filter paper or a membrane before testing.

· For samples prone to crusting, sugar-containing or heat-sensitive samples, select the "Gentle" mode and lower the temperature appropriately.

· Preheat the instrument before use and perform external weight calibration regularly.

The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top