Water quality microbial detector
manufacturer:Shandong Horde Electronic Technology Co., Ltd.
Introduction:The manufacturer of Water quality microbial detector「Horde Electronic」 has mastered the research and development technology of Water quality microbial detector, with more than 10 years of experience in manufacturing Water quality microbial detector. The quality is reliable, the detection accuracy is high, and the price competitive advantage of the source manufacturer is obvious. Welcome to call for more information.
Update time:2025-06-15
- Contact: Contact Information
- Phone:008618863942319
Product Recommendation
Product Details
Instrument Overview
The water quality microbial detector is an upgraded product developed and launched by our company in Shandong. It has a large touch screen instead of traditional buttons. The operation uses a biochemical reaction method to detect the ATP content. The ATP fluorescence detector is based on the principle of firefly luminescence. The ATP rapid bactericidal effect detection method is based on the ATP (adenosinetriphosphate) triphosphonic acid acyl glycoside detection principle, and uses the "luciferase-luciferin system" to quickly detect adenosine triphosphate (ATP). The ATP swab contains a reagent that can lyse the cell membrane, which can release ATP in the cell, react with the specific enzyme contained in the reagent, generate light, and then use a fluorescent illuminometer to detect the luminescence value. The number of microorganisms is proportional to the luminescence value. Since all living cells contain a constant amount of ATP, the ATP content can clearly indicate the amount of microorganisms and other biological residues in the sample, which is used to judge the sanitary conditions.
Functional features
Practicality - upper and lower limits can be set according to environmental testing needs to achieve rapid data evaluation and early warning;
By recording the relative light unit value (RLU) of the monitoring surface, the quality of environmental surface cleaning work can be assessed;
High sensitivity - 10-15~10-18mol;
Fast speed - conventional culture method takes more than 18-24 hours, while ATP only takes more than ten seconds;
Feasibility - There is a clear correlation between the number of microorganisms and the ATP contained in the microorganisms. By detecting the ATP content, the number of microorganisms in the reaction can be indirectly obtained;
Operability - traditional culture methods need to be operated by trained technicians in the laboratory; and ATP rapid cleanliness detection is very simple and can be operated on-site by general staff with simple training;
Better experience - the test tube adopts a plug-in flexible design, which can be cleaned regularly for long-term use to extend the life of the instrument;
Data export - the instrument is equipped with a host computer software, which is connected to the computer through a data cable to output the stored data in the form of Excel tables.
Technical indicators
1. Display screen: 3.5-inch capacitive touch display screen, real-time display of the current charging status and battery status of the system;
2. Operating system: 32-bit high-speed data processing chip;
4. Detection accuracy: 1×10-18mol;
5. Detection range: 0-99999RLUs;
6. Detection time: 15 seconds;
7. Background noise value: ≤6RLU (n=10);
8. Detection limit: 9.4×10-15molATP, RLU indication value is ≤2;
9. Repeatability: The instrument indication value is 100RLU When the instrument indicates about 100RLU, the relative standard deviation of repeated measurements is ≤2.3% (n=10);
10. Linear error: When the instrument indicates about 100RLU, the linear error of the measurement is ≥-3.6%;
11. Operating temperature range: 5℃ to 40℃;
12. Operating humidity range: 20-85﹪;
13. ATP recovery rate: 90-110%;
14. Detection mode: RLU;
15. 50 user ID settings, the number of settable result limits: 251;
16. Automatic judgment of qualified and unqualified;
17. Can be set Upper and lower limits;
18. Automatic statistics of qualified rate;
19. Built-in self-calibration light source;
20. Self-check for 30 seconds after power on;
21. Equipped with miniUSB interface, data can be directly exported by connecting to the computer via a data cable without external software;
24. Instrument size (W×H×D): 188mm×77mm×37mm;
25. Built-in 3200mAh lithium battery for power supply, standby time of more than 10 hours;
26. Stable liquid luciferase;
27. Wet integrated collection swab;
28. Meet JJF1828- 2020ATP fluorescence detector calibration specification, the instrument has a test report from the Institute of Metrology;
29. Meet WS/T512-2016 Medical Institution Environmental Surface Cleaning and Disinfection Management Specifications, A.1.2.3 Record the relative light unit value (RLU) of the monitoring surface to assess the quality of environmental surface cleaning work;
Application Field
Water quality microbiological detectors are widely used in: food and drug supervision, food, medical and health, medicine, medical equipment, daily chemicals, papermaking, industrial water treatment, national defense, environmental protection, water administration, customs entry and exit quarantine and other law enforcement departments and other industries.
Instrument Configuration
01 Host (handheld) 1 unit
02 U disk (driver, data analysis software) 1 unit
03 PC data cable 1 unit
04 Power adapter 1 unit
05 Manual 1 unit
06 Certificate of conformity, warranty card 1 set
07 Surface detection swabs (20 pieces) 1 package
08 Aluminum alloy suitcase 1 unit
Product's Website:http://en.huoerd.com/wswjcyq-5/1940.html