Haze Meter (Transmittance and Haze Meter) measures the light transmittance and haze of transparent and semi-transparent materials, plastic films and glass. Widely used for plastic film, glass and optical material quality control....

  • Image and Text Display
  • Technical Specifications
  • Product video

I. Product Introduction

The haze meter is an instrument used to determine the optical properties of transparent and translucent parallel-plane materials and plastic films. When a beam of parallel light enters a medium (such as transparent plastic), due to the inhomogeneity of the optical properties of the material, surface defects, inhomogeneity of internal structure, presence of bubbles and impurities, etc., the beam changes direction (diffusion and deflection). The resulting partially disordered light is called scattered light. Internationally, the ratio of the scattered luminous flux deviating from the incident light direction after passing through the specimen to the transmitted luminous flux, expressed as a percentage, is the so-called haze. A specimen with high haze will appear more blurred.

II. Application Scope

Used for transmittance and haze measurement of colorless transparent materials.

1. Plastics industry: used to evaluate the quality of plastic films and sheets, such as the haze of polyethylene (PE) and polypropylene (PP), to ensure that their transparency and optical properties meet production requirements. Detects the appearance of plastic packaging materials such as food packaging and pharmaceutical packaging.

2. Glass manufacturing: measures the haze of architectural glass and automotive glass to judge visual clarity and optical uniformity; helps optimize glass production processes and improve product quality.

3. Coatings and paints: determines the haze of coatings formed on different substrates to evaluate their gloss and appearance; used to compare the optical properties of different formulations when developing new coatings.

4. Display industry: detects the haze of liquid crystal displays (LCD) and organic light-emitting diodes (OLED) to ensure screen display effect and visual experience.

5. Optical materials: evaluates the haze of optical lenses, prisms and other components for precise analysis of their optical performance.

6. Lighting field: measures the haze of lamp shades and diffuser plates to achieve ideal light distribution and softness.

7. Medical industry: detects the haze of transparent materials used in medical devices such as infusion tubes and protective masks; used for transparency testing of drugs.

8. Chemical industry: used to determine the transparency of liquid solutions and help control the production process.

9. Food industry: detects the quality of juice, beverages and other products.

10. Environmental protection: monitors water quality, etc.

III. Executive Standards (selected)

GB/T 2410-2008 "Determination of luminous transmittance and haze of transparent plastics"

HG/T 5065-2016 "Clear varnish for architectural coatings"

GB 14866-2023 "General technical specifications for eye and face protection"

ASTM D1003-07 "Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics"

JIS K7105-1981 "Testing methods for optical properties of plastics"

JJF 1303-2011 "Calibration specification for haze meters"

BS ISO 14782-2021 "Plastics - Determination of haze for transparent materials"

IV. Product Features

1. Efficient, accurate and fast determination: relying on a standardized operating process and precisely controlled test conditions, detection is fast and efficient, ensuring consistency and accuracy of results. A human-eye response detector is used, whose spectral response curve almost completely matches the visual function Y/V(λ), capable of simulating and quantifying human eye observation.

2. Simple operation and high degree of automation: uses an LED light source simulating the CIE standard illuminant, with a longer life and immediate use without warm-up.

3. Excellent safety performance: equipped with a 12 V safety voltage adapter; the whole machine operates at low power with little heat generation, safe and reliable.

4. Convenient measurement and wide sample adaptability: an open measurement area supports both vertical and horizontal test postures, easily adapting to various sample forms. The standard 0/d optical structure makes test data more accurate and avoids surface reflection interference. It simultaneously meets the three major haze standards GB/T 2410, ASTM D 1003/1004 and ISO 13468/14782, with strong compatibility.

5. Ultra-long life and precise measurement: LED light source life up to 5 years or 5 million measurements, durable. Resolution up to 0.01 and repeatability accuracy of 0.05 ensure accurate and reliable measurement data.

6. Massive storage and convenient operation: a single unit can store 20,000 sets of test data, meeting large-volume inspection needs. Equipped with a capacitive touchscreen for smooth and sensitive operation; a 7-inch IPS full-view display with clear and transparent display. External start measurement button for more convenient operation.

7. Intelligent networking and system upgrade: supports WiFi networking, can automatically calibrate instrument timing and supports remote system upgrade for easy device performance optimization.

8. Permission grading and data security: supports multi-level user permission management, allowing creation of multiple users and assignment of different operation permissions to each, facilitating experimental traceability and data security control.

9. Data display and export: the data display interface can compare multiple samples simultaneously, making differences between samples clear at a glance. Equipped with a USB interface to support comprehensive data export for subsequent analysis and management.

V. Technical Parameters

ParameterHZ1HZ2HZ3
Operation7-inch touchscreen
Light sourceLED light source calibrated to C illuminant (380 nm~780 nm)
Compliant standardsGB/T 2410-2008, ASTM D1003-07, BS ISO 14782-2021
Optical path structure0/D
Spectral responseCIE spectral function Y/V(λ)
Measurement aperture21 mm21 mm, 7 mm
Repeatability0.08
Resolution0.01
Haze dataASTM
Measurement rangeTransmittance 0%-100%; haze 0%-100%
Data interfaceUSB interface
Instrument languageSupports Chinese/English one-key switching
Ambient temperature(5~40) °C
Ambient humidity≤85% RH
Power supplyDC 12 V/3 A
Dimensions470 mm × 270 mm × 170 mm
Sample chamber height150 mm (open)
Weight≤5.5 kg
The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top