Model:
HD-GC
Introduction:
Gas Chromatograph for Blood Ethanol Detection separates and analyzes blood alcohol content with a headspace sampler. Widely used in forensic, traffic safety, disease control, food and petrochemical laboratories....
The HD-GC Gas Chromatograph is a high-performance laboratory gas chromatography system. With an advanced PID temperature control system, a stable gas path design and a powerful data workstation, it delivers reliable qualitative and quantitative analysis of complex samples. The instrument adopts a 7-inch touch-screen display, supports network remote control and automatic FID ignition, and is widely used in environmental protection, disease control, food, quality supervision, mining and energy, petroleum refining, chemical engineering, health, electric power and liquor analysis, as well as in universities and research institutes.
The manufacturer is a professional developer, producer and supplier of gas chromatographs, headspace samplers, hydrogen generators, nitrogen generators, air generators, chromatographic accessories and other analytical instruments. Products are applied in environment, disease control, food, quality supervision, mining and energy, petroleum refining, chemical engineering, health, electric power, liquor and many other fields as well as in universities and research institutes. Relying on the local important scientific research and education base, the company continuously innovates, strengthens cooperation with sample enterprises, and introduces technology and talent, committed to being an analytical instrument manufacturer providing overall solutions.
| Parameter | Specification |
|---|---|
| Temperature control zones | 7 zones |
| Temperature control accuracy | ±0.1℃ to ±0.2℃ |
| Temperature control range | Room temperature +8℃ to 450℃, in 1℃ increments |
| Programmed temperature rise | 16-step programming; heating rate 0.1-40℃/min in 0.1℃ increments; initial and final time range 0-6000 min in 1 min increments |
| Limit temperature | Maximum protection value 450℃ |
| External events | 6 channels |
| Gas path control | Mechanical valve control |
| Detectors | 3 (2 × FID, 1 × TCD) |
| Injectors | Up to 3 (packed-column injector, capillary-column injector, valve injection) |
| Power supply | 220V 50Hz 2000 W |
| Item | Specification |
|---|---|
| Detector | Hydrogen flame ionization detector (FID) |
| Detection limit | Mt ≤ 5×10⁻¹¹ g/s (n-hexadecane / isooctane solution) |
| Noise | ≤ 5×10⁻¹⁴ A |
| Drift | ≤ 1×10⁻¹³ A/30 min |
| Ignition mode | Automatic ignition |
| Detector | Thermal conductivity detector (TCD) |
| Sensitivity | S ≥ 3500 mV·ml/mg (standard); 5000 mV·ml/mg (high sensitivity) (benzene-toluene solution) |
| Noise | ≤ 0.01 mV |
| Baseline drift | ≤ 0.03 mV/30 min |
| Linear range | ≥ 10⁴ |
Unlike an ordinary gas chromatograph, the system requires a 10/100 M adaptive network environment (an Internet access service is additionally required when remote data transmission over the Internet is needed) together with a computer running a Chinese Windows 2000 / XP / Win7 / Win8 operating system. Through the remote-control workstation software, the instrument can be monitored, data acquired, spectra processed, results calculated and reports printed directly from the computer.