EN
Position:Home>Products>Spectral Analysis>Atomic Spectrum>Flame Photometer>Flame Photometer

Products

Flame Photometer

Model:

HD-FP3C

Introduction:

Flame Photometer, based on atomic emission (flame photometry), measures the concentration of alkali and alkaline-earth metals such as potassium, sodium, calcium and lithium in solution. Widely used in agriculture, soil testing, cement, ceramics and glass industries....

  • Image and Text Display
  • Technical Specifications
  • Product video

I. Product Introduction

The flame photometer is a relative measurement instrument based on the principle of atomic emission spectrometry (flame color reaction), mainly used to determine the concentration of alkali metal and alkaline earth metal elements (such as potassium, sodium, calcium and lithium) in solutions. The concentration value of the tested sample is a relative value against the concentration of a standard solution under the same test conditions. Before testing, a set of standard solutions must be prepared, then a calibration operation is performed, a standard curve is drawn manually or by the instrument, and finally the tested sample is measured to obtain its concentration value or other required calculation data.

II. Application Range

It can be widely used in pre-treatment requirements for environmental monitoring, agriculture and fertilizer industries, food industry, chemical manufacturing, medical and clinical diagnosis, geological mining and new energy industries.

III. Executive Standards (partial)

JJG 630-2007 "Flame photometer"

LY/T 1246-1999 "Determination of exchangeable potassium and sodium in forest soil"

LY/T 1248-1999 "Determination of exchangeable sodium in alkaline soil"

LY/T 1254-1999 "Determination of total potassium and total sodium in forest soil"

NY/T 889-2004 "Determination of available potassium and slowly available potassium in soil"

NY/T 2420-2013 "Determination of total potassium in plants - Flame photometric method"

IV. Features

1. Adopts a 7-inch color capacitive touch LCD screen; convenient to operate, small in size, stable and reliable.

2. Has the function of direct concentration reading for five elements: potassium, sodium, lithium, calcium and barium; able to simultaneously measure 3 elements in any combination.

3. High-transmittance, extremely low stray-light filters reduce background interference to obtain a higher signal-to-noise ratio.

4. One-key ignition function, convenient and fast; uses a built-in silent air pump with no need for an additional air compressor.

5. Uses a self-developed high-performance nebulizer, with uniform and efficient atomization and smooth and stable sample aspiration, ensuring the accuracy and stability of sample analysis results.

6. Can store up to 10 points per set of standard curve parameters, with a total of 20 curve data sets savable.

7. Equipped with a moisture separator to avoid the influence of environmental changes and ensure stable analysis results.

8. Equipped with a flameout protection device, with the function of automatically closing the gas solenoid valve after flameout.

9. Equipped with a single-point calibration function, allowing quick correction when the baseline drifts.

10. Equipped with a historical record printing function and USB flash drive export function.

V. Technical Parameters

ItemHD-FP2HD-FP3AHD-FP3BHD-FP3CHD-FP4HD-FP5
Test elementsNa, KNa, K, CaNa, K, LiNa, K, BaNa, K, Li, CaNa, K, Li, Ca, Ba
Number of channels233345
Operation modeScreen touchScreen touchScreen touchScreen touchScreen touchScreen touch
Dispersion modeInterference filterInterference filterInterference filterInterference filterInterference filterInterference filter
Photoelectric conversion elementSilicon photocellSilicon photocellSilicon photocellSilicon photocellSilicon photocellSilicon photocell
Printing functionBuilt-in thermal printerBuilt-in thermal printerBuilt-in thermal printerBuilt-in thermal printerBuilt-in thermal printerBuilt-in thermal printer
USB data outputHistory exportable via USB flash driveHistory exportable via USB flash driveHistory exportable via USB flash driveHistory exportable via USB flash driveHistory exportable via USB flash driveHistory exportable via USB flash drive
Concentration calculation methodSegmented method, linear fitting, curve fittingSegmented method, linear fitting, curve fittingSegmented method, linear fitting, curve fittingSegmented method, linear fitting, curve fittingSegmented method, linear fitting, curve fittingSegmented method, linear fitting, curve fitting
StabilityContinuous injection of standard solution: within 15 s, relative maximum variation of the instrument reading ≤3%; measured once per minute, 6 times total, maximum variation of the instrument reading ≤8%SameSameSameSameSame
Repeatability≤2%≤2%≤2%≤2%≤2%≤2%
Response time≤8 s≤8 s≤8 s≤8 s≤8 s≤8 s
Sample aspiration rate≤6 mL/min≤6 mL/min≤6 mL/min≤6 mL/min≤6 mL/min≤6 mL/min
Linearity error (mmol/L) NaNa ≤0.02Na ≤0.02Na ≤0.02Na ≤0.02Na ≤0.02Na ≤0.02
Linearity error (mmol/L) KK ≤0.003K ≤0.003K ≤0.003K ≤0.003K ≤0.003K ≤0.003
Linearity error (mmol/L) Li--Li ≤0.007-Li ≤0.007Li ≤0.007
Linearity error (mmol/L) Ca-Ca ≤0.062--Ca ≤0.062Ca ≤0.062
Linearity error (mmol/L) Ba---Ba ≤0.066-Ba ≤0.066
Detection limit (mmol/L) NaNa ≤0.007Na ≤0.007Na ≤0.007Na ≤0.007Na ≤0.007Na ≤0.007
Detection limit (mmol/L) KK ≤0.0005K ≤0.0005K ≤0.0005K ≤0.0005K ≤0.0005K ≤0.0005
Detection limit (mmol/L) Li--Li ≤0.012-Li ≤0.012Li ≤0.012
Detection limit (mmol/L) Ca-Ca ≤0.037--Ca ≤0.037Ca ≤0.037
Detection limit (mmol/L) Ba---Ba ≤0.066-Ba ≤0.066

Detection range (ppm)Na: 0.18-100; K: 0.15-100; Li: 0.1-30; Ca: 0.1-1000; Ba: 0.1-300
Filter center wavelength errorNa ≤5 nm; K ≤7 nm; Li ≤7 nm; Ca ≤7 nm; Ba ≤7 nm
Filter bandwidth≤15 nm
Normal working conditionsAmbient temperature: 10 ℃ ~ 35 ℃; relative humidity: ≤85%
Main unit dimensions460 mm (L) × 325 mm (W) × 450 mm (H)
Net weight13 kg ±1 kg
Power supply and power220 V ±22 V, 50 Hz ±1 Hz, ≤50 W
The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top