HD-NC500Z

Introduction:

Gel Imaging Instrument (Gel Documentation System) captures and analyzes images of DNA/RNA electrophoresis gels, protein gels and dot blots with a high-resolution camera. Widely used in molecular biology, biochemistry and research laboratories....

  • Image and Text Display
  • Technical Specifications
  • Product video

Product Introduction

The HD-NC500Z Gel Imaging and Analysis System (UV) is suitable for the acquisition and analysis of images of DNA/RNA electrophoresis gels, protein electrophoresis gels and dot blots. It uses a high-resolution camera matched with a high-sensitivity lens to guarantee high-quality imaging results. Two configurations are available: UV imaging with a high-efficiency and stable ballast, with rectifier efficiency η > 80%, extending lamp life and reaching an average of up to 40,000 power-on/off cycles.

Application Range

  • Nucleic acid detection: DNA/RNA detection labeled with various fluorescent dyes such as Ethidium bromide, SYBR Gold, SYBR Green, GelSafe, GelRed, GelGreen, SYBR Safe, GelStar, Fluorescein, Texas Red, Oligreen and Picogreen.
  • Protein detection: Coomassie Brilliant Blue gels, silver-stained gels, and gels/membranes/chips labeled with dyes such as Coomassie Blue, Copper stain, Zinc stain, Flamingo, Oriole, Silver stain, Coomassie Fluor Orange, SYPRO Ruby and Krypton.
  • Other applications: Petri dish colony counting, microplates, dot blots and protein chips.

Product Features

  • High-resolution camera and high-sensitivity original imported lens guarantee high-quality imaging results.
  • Large observation field with a dedicated gel-cutting protective cover for more comfortable and safer operation.
  • Intelligent operating software allows zoom, focus, light source switching and shooting to be fully controlled from the computer, ensuring diversified functions while keeping the interface concise and intuitive.

Technical Parameters

ParameterSpecification
CameraImported high-resolution research-grade camera
Camera chipOriginal imported CCD
Effective pixels2592 × 1944 (5.03 million)
Pixel density16 bit (65536 gray levels)
Pixel size5.2 μm × 5.2 μm
Photosensitivity0.78
Signal-to-noise ratio69.8 dB
Readout noise5.1 e- RMS
Detection sensitivityCan detect nucleic acids as low as 0.02 ng
LensOriginal imported high-transmittance 6× motorized zoom lens, F1.2, 8-48 mm; one-key auto-focus can automatically focus on the sample without manual adjustment
FilterImported 590 nm; other filters optional
Transmissive UVStandard 302 nm with high-efficiency rectifier, rectifier efficiency η > 80%, lamp average power-on/off cycles up to 40,000 (254 nm and 365 nm optional)
Transmissive white lightStandard 6-level adjustable brightness LED white light plate
Transmissive blue light470 nm optional
Episcopic UV254 nm / 365 nm / 470 nm optional
Episcopic white lightHigh-brightness LED cold light sources on both sides
UV transmission area210 × 260 mm; visible-light transmission area 210 × 260 mm
Gel-cutting deviceStandard dedicated gel-cutting device
Module controlHighly programmed, realizing fully automatic modular control of the lens module (zoom / focus / aperture), transmissive and reflective light sources and gel-cutting light source
Timed light-offUV light source automatically turns off after 1-60 minutes of no operation, effectively extending the service life of the UV lamp
StructureSealed light-tight microprocessor-controlled darkroom
ProtectionAutomatic door-opening protection system to prevent ultraviolet injury

Intelligent Software

  • Image capture: light source / lens / camera control, automatic / manual exposure, automatic / manual focus, image capture and image management.
  • Hidden function settings: part of the functions can be freely chosen to be displayed or hidden to keep the software interface concise.
  • Image processing: adjust brightness, contrast, Gamma, image rotation, image inversion, image cropping, image scaling, image staining and image merging.
  • Analysis functions: automatic / manual lane identification and band identification; manual addition and deletion of lanes and bands; user-defined molecular weight standards for molecular weight and concentration calculation.
  • Printing and grid lines: the operating software includes a direct printing window; grid-line function allows easy comparison with the Marker.
  • Save path: default image save path can be set so that no manual saving is required; a custom save path can be set before shooting.
  • Other analysis functions: colony and dot-blot / clone counting.
  • Data export: results can be exported to Excel.
  • Service: the software is installed, upgraded and trained on site free of charge for life, and on-site maintenance is provided according to customer needs.

Standard Configuration

  • Imaging host: 1 unit
  • Data cable: 2 pieces
  • Power cable: 1 piece
  • Certificate / warranty card: 1 copy
  • Transmissive white light plate: 1 piece
  • Gel-cutting cover: 1 piece
  • Software USB flash drive: 1 piece
The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top