Dual system automatic injection ion chromatograph
manufacturer:Shandong Horde Electronic Technology Co., Ltd.
Introduction:The manufacturer of Dual system automatic injection ion chromatograph「Horde Electronic」 has mastered the research and development technology of Dual system automatic injection ion chromatograph, with more than 10 years of experience in manufacturing Dual system automatic injection ion chromatograph. The quality is reliable, the detection accuracy is high, and the price competitive advantage of the source manufacturer is obvious. Welcome to call for more information.
Update time:2025-06-14
- Contact: Contact Information
- Phone:008618863942319
Product Recommendation
Product Details
1. Product introduction:
HD-TLS40 dual-system automatic injection ion chromatograph is a valve switching dual-system ion chromatograph built for customers. It also has anion and cation suppressor system, built-in 90-position automatic sampler, realizes fully automatic detection function, and reserves the eluent generator interface for seamless docking. The conductivity cell constant temperature, the Du box constant temperature and the one-key start of injection are all standard features of the instrument, forming a more powerful detection system.
3. Product features:
1. Diversification of detectors and pump systems, optional conductivity detectors, ampere detectors, ultraviolet detectors, equipped with integrated rotary automatic samplers and single pumps, dual pumps and gradient pumps and other different configurations.
2. The whole system is equipped with PEEK material flow path as standard. Including the analysis pump itself and all pipelines from the analysis pump to the six-way valve, chromatographic column, suppressor, and detector, effectively preventing acid and alkali corrosion.
3. The control software must have one-key flushing and one-key maintenance functions.
4. Pump: High-performance/low-pulse low-pressure quaternary double plunger pump, chemically inert non-metallic non-damping pump head, PEEK pipeline. Suitable for eluents and reversed organic solvents with a pH of 0 to 14. Analytical isocratic pumps and analytical quaternary gradient pumps can be selected as needed.
5. Structure: Dual-electrode tubular conductivity cell, internal structure temperature control. Realize good sample accuracy and reproducibility under constant temperature, digital signal control processor, when detecting ions of different concentrations from μg/L to g/L, the output signal can be directly digitally expanded without adjusting the range, the output value should be a direct conductivity signal, and provide a chromatogram with conductivity output.
6. The anion suppressor can be regenerated by electrolysis without adding acid. The operation is simple. In order to save customers' understanding of the suppressor, the company can provide a five-year warranty service.
7. Temperature-controlled column box plus conductivity cell dual constant temperature control, heating method: contact or blast.
8. Digital signal transmission with computer via high-performance Bluetooth, analysis methods and sequences can be compiled.
9. Graphical reverse control interface, providing real-time analysis condition parameters and analysis results, online modification and collection of working parameters of each component, automatic rapid data collection and post-processing, with instrument-related data and operating status traceability function, convenient troubleshooting.
10. Supports the establishment and call of instrument analysis methods and data processing templates. The online automatic sampler does not need to rename the collected spectrum data. It supports the change and call of sample analysis methods without stopping the machine, realizing unattended analysis.
4. Technical parameters:
1. [Dual plunger constant flow pump system]
Flow rate: 0.001-10.000mL/min
Maximum pressure resistance: 42Mpa
Maximum flow rate error: ≤0.1%
Flow rate precision: ≤0.1%
Pressure pulse: ≤1.0% of system pressure
Pressure display accuracy: 0.001Mpa
2. [Conductivity detector structure]
Conductivity cell volume: ≤0.2μL
Baseline noise: 0.001μS
Detection range: 0-15000μS/cm
Detector resolution: <0.005nS/cm
Baseline drift: 0.02μS/30min,
Detector maximum pressure tolerance: >12Mpa
Conductivity cell electrode material: passivated titanium alloy
3. [Ion suppressor]
Equipped with anion and cation suppressor;
Constant current source range: 0-300mA, increment 0.1mA;
4. [Digital three-dimensional column oven]
Temperature control range: room temperature—+60℃
Column oven temperature setting error value 0.04℃
Temperature stability 0.1℃
Compatible chromatographic columns: two 250mm chromatographic columns and one anion and cation suppressor each.
5. [Automatic sampler system]
①Built-in integrated automatic sampler, integrated with the host;
②Three injection modes (full quantitative loop injection, partial injection, micro injection);
③Sample position: not less than 90*2.0ml position;
④Sampling speed: 0.1-3.0ml/min;
⑤Qualitative measurement repeatability: 0.05%, quantitative measurement repeatability: 0.1%;
⑥Connection method: Bluetooth, USB;
⑦Needle washing method: ultrapure water peristaltic pump cleaning device;
6. [Eluent automatic generation module]
①Contains 1 anion eluent automatic generator (built-in in the host);
②1 potassium hydroxide eluent tank;
③Eluent concentration range: 0.1-100mM/L;
④Use H+ or OH- generated by online electrolysis to generate acidic or alkaline eluent, which can effectively avoid the influence of air and prevent the change of mother liquor from affecting the eluent. It cannot be replaced by dilution. Easy to operate, directly input the required eluent concentration in the software, without the user having to write other non-concentration parameters;
⑤ Flow rate range: 0.1-3.0mL/min;
⑥ Concentration increment: 0.1mM;
⑦ Gradient elution can be performed;
【Working conditions】
Working power supply: 220V, 50HZ
Ambient temperature: +5℃~+36℃
Relative humidity: <85%
Product's Website:http://en.huoerd.com/lzspy/1745.html