Scientific instrument deep service provider

Water Quality Testing  Agricultural Ecology  Food Rapid Inspection  Life Sciences  Meteorological Environment


Phone:008618863942319

search COD meter    Multi-parameter water quality meter    Ammonia nitrogen meter
Atomic absorption spectrophotometer Update time:2025-06-13
Atomic absorption spectrophotometer

Atomic absorption spectrophotometer

Model:HD-AAS6HS
Price:Please contact customer service for discounted prices

manufacturer:Shandong Horde Electronic Technology Co., Ltd.

Introduction:The manufacturer of Atomic absorption spectrophotometer「Horde Electronic」 has mastered the research and development technology of Atomic absorption spectrophotometer, with more than 10 years of experience in manufacturing Atomic absorption spectrophotometer. The quality is reliable, the detection accuracy is high, and the price competitive advantage of the source manufacturer is obvious. Welcome to call for more information.

Update time:2025-06-13

Product Recommendation

Product Details

1. Product Introduction:

HD-AAS6HS flame graphite furnace integrated atomic absorption spectrophotometer has high analysis accuracy and thoughtful humanized design, which can fully meet the various specific needs of different customers. And according to different analysis needs, automatic sample injector, hydride generator, etc. can be selected.

2. Application Field:

It can be widely used in geology, metallurgy, medicine, chemical industry, petroleum, agriculture, environmental protection, commodity inspection and other industries. The analysis and application of trace elements has gradually penetrated from inorganic chemistry to organic chemistry in recent years.

3. Performance characteristics

1. Four, six, and eight lamp positions are optional (high-performance element lamps are optional), automatic three-dimensional switching, energy balance, and simultaneous preheating of multiple lamp positions to save waiting time, with deuterium lamp background clipping and self-absorption background clipping functions;

2. Unique integrated design of flame atomizer and graphite furnace atomizer to achieve automatic switching and manual switching dual modes;

3. Automatic optimization and memory function of instrument setting conditions, one-click completion of scanning peak search and energy balance;

4. Data reports are saved and printed in multiple formats to facilitate data query and comparison;

5. The instrument software adopts a single-interface multi-function window design to make operation simpler, real-time monitoring of data changes, support for mainstream Windows operating systems, support for remote control and calibration, Chinese/English Optional version, with comprehensive quality control (QC) function;

6. Advanced and reliable multiple safety protection system, automatic detection, alarm, such as insufficient pressure, leakage, flameout and other abnormal conditions;

7. Expandable: hydride system and combined functions;

4. Technical indicators:

1. Optical system

Detector: Hamamatsu photomultiplier tube;

Wavelength range: 185nm-900nm;

Wavelength indication error: ≤±0.1nm;

Wavelength repeatability: ±0.025nm;

Baseline drift: 0.003ABS/30min (static) ↵0.005ABS/15min (dynamic);

Spectral bandwidth deviation (resolution): Cu324.7nm wavelength 0.2nm bandwidth half width 0.2n m±0.01nm;

Light source system: turret type fully automatic switching lamp holder;

Element lamp lighting mode: 400Hz1/4 duty cycle pulse lighting;

Lamp current adjustment: (0-10)mA (average current) software adjustment;

Monochromator type: Czerny-Turner enhanced type;

Grating line density: 1800;

Spectral bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.0nm multi-speed automatic switching;

2. Flame atomization system

Burner: 0.5mmX100mm all-titanium burner;

Sprayer: Metal sleeve high-efficiency glass sprayer;

Repeatability: RSD≤0.7%;

Detection limit: ≤0.006ug;

3. Graphite furnace atomization system

Detection Limit: 1.5pg;

Precision: ≤3%;

Heating temperature range: room temperature-3000℃;

Heating speed: 2000℃/s;

Temperature control accuracy: 1%;

Heating condition setting: 11 steps, ramp heating, step heating, maximum power heating, heating monitoring and reverse measurement system;

Safety protection: air pressure system, cooling system fault protection, power monitoring;

Background correction (deuterium lamp): ≥60 times at 1ABS;

Background correction (self-absorption): ≥60 times at 1ABS;

Data processing: Linear regression method automatically fits the working curve and automatically calculates the results;

Number of samples: 1-99;

Result output: multi-format data storage and print output;

Communication interface: standard RS232, USB expansion interface;