Scientific instrument deep service provider

Water Quality Testing  Agricultural Ecology  Food Rapid Inspection  Life Sciences  Meteorological Environment


Phone:008618863942319

search COD meter    Multi-parameter water quality meter    Ammonia nitrogen meter
Portable handheld Update time:2025-06-15
Handheld biological toxicity detector

Handheld biological toxicity detector

Model:HED-DXS
Price:Please contact customer service for discounted prices

manufacturer:Shandong Horde Electronic Technology Co., Ltd.

Introduction:The manufacturer of Handheld biological toxicity detector「Horde Electronic」 has mastered the research and development technology of Handheld biological toxicity detector, with more than 10 years of experience in manufacturing Handheld biological toxicity detector. The quality is reliable, the detection accuracy is high, and the price competitive advantage of the source manufacturer is obvious. Welcome to call for more information.

Update time:2025-06-15

Product Recommendation

Product Details

1. Product Overview:

The HD-DXS handheld biological toxicity detector is a new generation of biological acute toxicity analyzer for laboratory use. It is a toxicity detection system based on bioluminescent sensing technology. It performs rapid qualitative detection based on the changes in the luminous intensity of luminous bacteria during metabolism. Compared with traditional fish, fleas and other aquatic organisms as biological detection methods, the luminous bacteria method is simple, rapid, sensitive, adaptable, repeatable, accurate, low-cost and widely used. It is a rapid water toxicity detection instrument designed for environmental pollution, emergency accidents, security inspections and routine inspections. It can be used for the overall toxicity detection of heavy metals, poisons, nerve agents, pesticide preparations and other substances in on-site water.

It complies with the national standard "GB/T15441-1995 Determination of acute toxicity of water quality-luminous bacteria method" and international standards (ISO11348-3).

2. Qualifications obtained by this product:

Software Copyright Certificate: "Handheld Biological Toxicity Detection System-Registration Number: 2022SR0076569";

Microbial strain identification report: "National Strain Resource Bank-China Agricultural Microbial Strain Collection Management Center-Report Number: Bacteria Inspection Number No. 20211116";

Related qualifications: High-tech enterprise, quality management system certification (ISO9000), environmental management system certification (ISO14001), occupational health and safety management system certification (ISO45001), registered trademark, metrology institute test report, etc.

3. Application Industry:

Handheld biological toxicity detectors are used in drinking water testing, emergency response-biological pollution, emergency response-toxic chemicals, toxic and hazardous waste, municipal drainage, rainwater testing, drilling fluid and mud testing, mining, wastewater, soil and water testing, industrial wastewater discharge testing, process water testing, seawater testing, medical/pharmaceutical product testing, food packaging testing, personal care products and household chemicals testing, sediment testing, rainwater runoff testing, solid sample testing, food processing water testing, etc.

4. Detection Principle:

The HD-DXS model performs triple functions: toxicity testing, ATP testing, and determining microbial contamination; toxicity testing is performed using luminescent bacteria that exist in nature. This type of bacteria emits light during normal metabolism. If placed in a toxic environment, their cell respiration process is affected, resulting in a decrease in the amount of light emitted. The HD-DXS luminescence detector measures the amount of light emitted by luminescent bacteria before and after exposure to a toxic environment, and the degree of reduction in the amount of light corresponds to the strength of the toxicity.

5. Instrument features:

1. Comply with national standards (GB/T154411995) and international standards (ISO11348-3);

2. A biological early warning system that is sensitive to more than 3,000 toxic compounds;

3. Fast, reliable and reproducible analysis results: Results are obtained within 15 minutes after sample preparation;

4. A simple, fast and highly sensitive portable water quality detector, specially designed for screening acute toxicity and adenosine triphosphate (ATP);

5. Android smart operating system, smarter and more user-friendly;

6. Combined with ATP detection function, on-site quantitative calculation of ATP concentration, enhancing the anti-interference ability of water quality toxicity detector, one machine with multiple functions;

7. Portable handheld design, more convenient for on-site detection;

8. The detection sleeve adopts a plug-in flexible design, which can be cleaned regularly for long-term use and extend the life of the instrument;

9. 3.5-inch true color touch screen, eliminating cumbersome buttons and making operation more convenient;

10. Using silicon photomultiplier tubes, greatly improving detection sensitivity;

11. With WIFI, The mobile phone hotspot networking and Bluetooth transmission functions can realize wireless transmission to relevant monitoring and supervision platforms, realize real-time data, and better meet the scene requirements of the regulatory department;

12. The instrument has a built-in 3500mAH lithium battery pack. When the external power is off or there is no power supply, the standby time is more than 10 hours;

13. A curve can make tens of thousands of curve concentration points, and the curve concentration points can be added by yourself without manual recording, ensuring that the curve value is more accurate;

14. The ATP mode can set the upper and lower line values, which is more convenient for random inspection to judge the qualified rate;

15. The instrument has a built-in ROM ≥ 4GB, and the data results can be stored for more than 80,000;

16. It has a USB communication interface for convenient data reading and export, and the export results are Excel tables;

17. Built-in Sogou input method, which can edit Chinese and English information;

18. Built-in web browser, Baidu can search for relevant literature after connecting to the Internet;

19. The standard mode has demonstration operation steps, which is convenient and fast, and easier to use;

20. Configure the cloud data management platform, the test results can be permanently stored, and long-term and short-term viewing and analysis are carried out to assist Management;

21. The instrument can be equipped with GPS satellite positioning function to display the location information of the field detection site in real time and store the positioning information;

6. Parameter indicators:

Measurement mode: fast measurement mode, basic measurement mode, ATP measurement mode;

Detector: silicon photomultiplier tube;

Spectral range: 300-1100nm;

ATP sensitivity: 10-15~10-18mol;

Bacterial species: Photobacterium luminescens, Vibrio fischeri, Vibrio qinghaiensis, Photobacterium aujuxiangensis, etc.;

Method standard: GB/ T15441-1995&ISO11348;

Measurement range: 0~999999RLU (relative luminescence unit);

ATP detection limit: 9.4×10-15molATP, RLU indication is ≤2;

ATP repeatability: when the instrument indication is about 100RLU, the relative standard deviation of repeated measurements is ≤2.3% (n=10);

ATP linear error: when the instrument indication is about 100RLU, the linear error of the measurement is ≥-3.6%;

Toxicity test accuracy :The sample was repeated 3 times, and the relative deviation was less than 6%;

Sensitivity: Equivalent to or better than the acute biological toxicity test method for fish body 96-hour culture determination;

Toxicity test time: Results are obtained within 15 minutes after sample preparation;

ATP test time: Results are obtained within 15 seconds after sample preparation;

Display results: Suppression rate (﹪) Relative luminescence (RLU) Toxicity prompt (low toxicity, toxicity, severe toxicity, high toxicity, extremely toxicity) are displayed according to national standards;

System settings: Upload address, sample name, tester, test location, contact number, etc. can be Self-set;

Background noise value: ≤6RLU (n=10);

Operating environment: storage temperature -10~50℃, working temperature +5~45℃;

Relative humidity: 30-95% (25°C);

Data storage: more than 80,000 records;

Communication: WIFI, hotspot, RS232, Bluetooth;

Battery: 3500mAh lithium battery;

Continuous working time: more than 10 hours;

Charging voltage: 220V/5V;

Instrument size: 188mm×77mm×37mm;

Product's Website:http://en.huoerd.com/bxscs/619.html