Biological toxicity detector
manufacturer:Shandong Horde Electronic Technology Co., Ltd.
Introduction:The manufacturer of Biological toxicity detector「Horde Electronic」 has mastered the research and development technology of Biological toxicity detector, with more than 10 years of experience in manufacturing Biological toxicity detector. The quality is reliable, the detection accuracy is high, and the price competitive advantage of the source manufacturer is obvious. Welcome to call for more information.
Update time:2025-06-15
- Contact: Contact Information
- Phone:008618863942319
Product Recommendation
Product Details
1. Product Overview:
The portable water quality biological toxicity detector is a new generation of biological acute toxicity analyzer for laboratory use. It is a toxicity detection system based on bioluminescent sensing technology. It performs qualitative and quantitative detection based on the changes in the luminous intensity of luminous bacteria during metabolism. Compared with traditional fish, water fleas and other aquatic organisms as biological detection methods, the luminous bacteria method is simple, rapid, sensitive, adaptable, repeatable, accurate, low-cost and widely used. It is a rapid water quality toxicity detection instrument designed for environmental pollution, emergency accidents, security inspections and routine inspections. It can be used for the overall toxicity detection of heavy metals, poisons, nerve agents, pesticide preparations and other substances in on-site water.
It complies with the national standard "GB/T15441-1995 Determination of acute toxicity of water quality-luminous bacteria method" and international standards (ISO11348-3).
2. Application industries:
Biological pollution, toxic chemicals, toxic and hazardous waste, municipal drainage, rainwater detection, drilling fluid and mud detection, mining industry, wastewater, soil and water detection, industrial wastewater discharge detection, process water detection, seawater detection, medical/pharmaceutical product detection, food packaging detection, personal care products and household chemicals detection, sediment detection, rainwater runoff detection, solid sample detection, food processing water detection;
3. Detection principle:
The portable water quality biological toxicity detector performs dual functions: toxicity testing and determining microbial contamination; toxicity testing is performed using luminescent bacteria that exist in nature. This bacteria emits light during normal metabolism. If placed in a toxic environment, their cell respiration process is affected, resulting in a decrease in the amount of light. The luminescence detector measures the amount of light emitted by the luminescent bacteria before and after exposure to the toxic environment. The degree of reduction in the amount of light corresponds to the strength of the toxicity. The test results can be compared with the standard toxic substances HgCl2 or zinc sulfate heptahydrate to obtain the corresponding toxicity level.
4. Instrument features:
1. Comply with national standards (GB/T154411995) and international standards (ISO11348-3);
2. A biological early warning system that is sensitive to more than 3,000 toxic compounds;
3. Results are obtained within 15 minutes after sample preparation, which is fast, reliable and reproducible;
4. The test results are highly correlated with other traditional toxicity analysis methods and can be applied to emergency water pollution detection to help users monitor in real time whether drainage complies with local regulations and emission standards;
5. Android smart operating system, smarter and more user-friendly;
6. It has an independently developed biological toxicity darkroom automatic lifting detection device to solve the problem of open-cover testing being affected by strong light in the industry; for the same amount of bacteria, our instrument can save 5 times the cost of consumables;
7. Portable PVC engineering box design, which can be carried out for on-site testing;
8. 7-inch ultra-large display touch screen, eliminating the cumbersome operation of buttons, more convenient;
9. Use silicon photoelectric Multiplier tube, greatly improving the detection sensitivity;
10. With RJ45, WIFI, 4G and Bluetooth connection transmission functions, it can realize wireless transmission to relevant monitoring and supervision platforms, realize real-time data, and better meet the scene requirements of the regulatory department;
11. The instrument has a built-in 6000mAH lithium battery pack, which can support continuous work for more than 8 hours in the case of external power failure or no power supply;
12. A curve can have 20 curve concentration points, and you can choose whether the curve point participates in the calculation of the entire curve at will, without manual recording, to ensure that the curve value is more accurate; (curve concentration points can be customized and increased)
13. The instrument has a built-in ROM ≥ 4GB, and the data results can store more than 80,000;
14. It has a USB communication interface for convenient data reading and export, and the export results are Excel tables;
15. Built-in Pinyin input method, which can edit Chinese and English information;
16. High-speed thermal printer, the test report can be automatically printed after the test is completed, and the test report is accompanied by a QR code for easy scanning Traceability;
17. The instrument has built-in operation demonstration video. Click the operation video on the main interface to play it automatically. It is convenient and easy to use;
18. The detection history query function can select the start and end time to retrieve the previous detection data, which is accurate and convenient;
19. Equipped with Holder Electronic Cloud Data Management Platform, the test results can be permanently stored for long-term and short-term viewing and analysis, and auxiliary management;
20. The instrument can be equipped with GPS satellite positioning function to display the location information of the field detection site in real time, and can print and store the positioning information;
5. Parameter indicators:
Detection method: luminous bacteria method
Detector: silicon photomultiplier tube
Spectral range: 300-1100nm
Bacteria: Bright Photobacterium, Vibrio fischeri, Vibrio qinghaiensis, Photobacterium osmoticum, etc.;
Method standard: GB/T15441-1995&ISO11348;
Repeatability: The sample is measured three times repeatedly, and the relative deviation is less than 1%;
Sensitivity: Equivalent to or better than the 96-hour culture determination of fish Acute biological toxicity test method;
Relative linear error (luminescence inhibition rate): prepare a zinc sulfate solution with a Zn2+ concentration of 1.13ml/L, and the relative linear error of its luminescence inhibition rate is ≤±10%;
Test time: get the result within 15 minutes after sample preparation;
Display results: quantitative detection (mg/L)/qualitative detection (low toxicity, moderate toxicity, severe toxicity, high toxicity, extremely toxicity)/inhibition rate (%);
Print settings: sample name, tester, test location, reference poison;
Operating environment: storage temperature -10~50℃, working temperature +5~45℃;
Relative humidity: 30-95% (25°C);
Data storage: more than 80,000 records;
Communication: RJ45, WIFI, 4G, USB, Bluetooth;
Battery: 6000mAh lithium battery;
Continuous working time: more than 8 hours;
Power supply: 220V/12V AC/DC;
Dimensions and weight: 420*330*175mm/5KG;
Product's Website:http://en.huoerd.com/swdxjcy/442.html