Products

Model:
HD-DJ17S
Introduction:
Oil-in-water Sensor measures soluble oil concentration in water by spectral absorption and emission with RS485 output. Widely used for industrial wastewater, petrochemical and environmental water monitoring....
The HD-DJ17S oil-in-water sensor makes use of the absorption and emission peaks of soluble oil in the spectrum. Monochromatic light at the absorption peak irradiates the water; the soluble oil absorbs the energy and releases monochromatic light at the emission peak. The intensity of the emitted light is proportional to the content of soluble oil in the water. The sensor is simple to install and easy to use.
1. Fluorescence method with a measuring range of 0–60 ppm.
2. Filter-based detection for strong interference immunity.
3. Internal signal isolation technology for strong interference immunity.
4. Good reproducibility, thermal stability and low drift, with a compact body and fast response.
5. 3/4 NPT pipe thread for simple immersion mounting, with stable performance and long service life.
6. IP68 waterproof rating.
7. Low power consumption: about 0.5 W at 12 V with the cleaning brush idle and about 1.5 W while the brush is running.
| Measurement principle | Fluorescence method |
| Signal output | RS485 (MODBUS-RTU) |
| Measurement range | 0–60 ppm |
| Detection limit | Determined by the actual oil sample |
| Accuracy | 0.1 ppm |
| Resolution | 0.01 ppm |
| Housing material | Glass and 316L stainless steel |
| Cable length | 5 m standard |
| Power supply | 12–24 VDC |
| Power consumption | At 12 V: approx. 0.5 W with the cleaning brush idle, approx. 1.5 W while the brush is running |
| Calibration | Two-point calibration |
| Operating environment | 0–50 °C (non-freezing), < 0.2 MPa |
| Waterproof rating | IP68 |
| Mounting | Immersion mounting, NPT 3/4 thread |
Keep at least 5 cm from the side wall and 10 cm from the bottom.
Do not work under strong light; keep the sensor in a dark environment as far as possible, and make sure that no other fluorescent substances that could be excited are present.
The cable is a 4-core shielded cable: red - power supply (12–24 VDC), blue - ground (GND), green - RS485-B, yellow - RS485-A. Check the wiring order carefully before powering on, to avoid unnecessary losses caused by incorrect connection. Cable colours may differ slightly between production batches; the colour print on the cable always prevails.
The measuring window is the key component that ensures correct operation and accurate measurement, so keeping it clean is essential. Clean the window periodically to remove dirt, deposits and other contaminants; the interval depends on the measuring environment, but daily or weekly cleaning is recommended. Use a mild detergent only - never abrasive, acidic or alkaline cleaners. Wipe the surface gently with a soft cloth or sponge, avoid touching it with bare hands so as to keep fingerprints and grease away, rinse thoroughly with clean water and dry with a soft dry cloth. Check the window regularly for damage or wear, and never expose it to aggressive chemicals or high temperatures. The window contains glass, so never scrape it with sharp or hard objects. The sensor contains sensitive optical components and precision electronics; protect it from violent vibration and impact. Fit the dust cap when the sensor is not in use. When measurement error appears after long service, recalibrate the sensor with a host instrument; if calibration and measurement are still impossible after maintenance, the sensor has failed and should be replaced.