EN
Position:Home>Products>Water Quality Testing>Online Water Monitoring>Sensors>Online Water Temperature Sensor

Products

Online Water Temperature Sensor

Model:

HD-DJ21

Introduction:

Online Water Temperature Sensor measures water temperature in real time online. Widely used for industrial cooling, wastewater treatment, aquaculture, environmental monitoring and HVAC systems to ensure efficient, safe operation....

  • Image and Text Display
  • Technical Specifications
  • Product video

I. Application

The HD-DJ21 online water temperature sensor is widely used in industrial cooling, wastewater treatment, aquaculture, environmental monitoring, HVAC systems and other fields. It monitors water temperature in real time so that systems run efficiently and safely: power plants and chemical plants monitor cooling water temperature to prevent equipment overheating, aquaculture farms regulate water temperature to promote growth, and environmental monitoring assesses the ecological health of water bodies. Because the working environment varies greatly, the sensor is waterproof, corrosion-resistant and immune to interference.

II. Key Features

1. Measuring range -20 to 85 °C with an accuracy of ±0.1 °C and a resolution of 0.1 °C.

2. RS485 (MODBUS-RTU) signal output.

3. Single-point calibration.

4. ABS housing with IP68 protection for long-term immersion.

5. NPT 3/4 thread for simple immersion mounting.

6. Low power consumption of 0.25 W at 12 V.

III. Technical Parameters

Signal outputRS485 (MODBUS-RTU)
Measurement range-20 to 85 °C
Accuracy±0.1 °C
Resolution0.1 °C
Housing materialABS
Cable length5 m standard
Power supply12–24 VDC
Power consumption0.25 W at 12 V
CalibrationSingle-point calibration
Waterproof ratingIP68
MountingImmersion mounting, NPT 3/4 thread

IV. Installation and Wiring

Keep at least 5 cm from the side wall and 10 cm from the bottom.

The cable is a 4-core shielded cable: red - power supply (12–24 VDC), blue - ground (GND), green - RS485-B, yellow - RS485-A. Check the wiring order carefully before powering on, to avoid unnecessary losses caused by incorrect connection. Cable colours may differ slightly between production batches; the colour print on the cable always prevails.

V. Maintenance and Care

When measurement error appears after long service, recalibrate the sensor with a host instrument. If maintenance no longer restores calibration and measurement, the sensor has failed and should be replaced.

The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top