Introduction:

Online Transparency Sensor measures water transparency using light scattering or absorption with high sensitivity and RS485 output. Widely used for water quality monitoring and wastewater treatment....

  • Image and Text Display
  • Technical Specifications
  • Product video

I. Application

The HD-DJ20 online transparency sensor measures water transparency using the scattering or absorption characteristics of light. With high sensitivity, fast response and real-time monitoring capability, it is widely used in water quality monitoring and wastewater treatment.

II. Key Features

1. RS485 (MODBUS-RTU) signal output with an infrared LED light source for strong interference immunity.

2. Measuring range 50–1000 mm with a resolution of 1 mm.

3. Internal signal isolation technology for strong interference immunity.

4. Good reproducibility, thermal stability and low drift, with a compact body and fast response.

5. 3/4 NPT pipe thread for simple immersion mounting, with stable performance and long service life.

6. IP68 waterproof rating.

7. Two-point calibration and an optional 4–20 mA current output.

III. Technical Parameters

Measurement principleScattered-light method
Signal outputRS485 (MODBUS-RTU)
Measurement range50–1000 mm
Resolution1 mm
Accuracy±5% (depending on sample homogeneity)
Housing materialGlass and ABS
Cable length5 m standard
Power supply12–24 VDC (approx. 0.4 W at 12 V)
CalibrationTwo-point calibration
Operating environment0–50 °C (non-freezing), < 0.2 MPa
Waterproof ratingIP68
MountingImmersion mounting, NPT 3/4 thread

IV. Installation and Wiring

Do not install the sensor upside down or horizontally; install it at an angle of at least 15° to the horizontal.

The cable is a 5-core shielded cable: brown - power supply (12–24 VDC), black - ground (GND), blue - RS485-A, green - RS485-B, yellow - 4–20 mA current output (may be left floating if unused). Check the wiring order carefully before powering on, to avoid unnecessary losses caused by incorrect connection. Cable colours may differ slightly between production batches; the colour print on the cable always prevails.

V. Maintenance and Care

Electrodes require periodic cleaning and calibration; the interval depends on the actual working conditions. Standard cleaning procedure: remove deposits with a soft brush (do not scratch the electrode surface), rinse with distilled water, then calibrate.

The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top