ATP Bioluminescence Detector

Model:

HD-ATP+

Introduction:

ATP Bioluminescence Detector measures ATP content by the luciferase-luciferin reaction to assess surface cleanliness. Widely used for food safety, catering, medical hygiene, water quality and environmental monitoring....

  • Image and Text Display
  • Technical Specifications
  • Product video

Product Introduction

This device is a newly upgraded product. It uses a biochemical reaction method to detect the ATP content. Based on the firefly luminescence principle, the ATP fluorescence detector uses the "luciferase-luciferin system" to rapidly detect adenosine triphosphate (ATP). The ATP swab contains a reagent that can lyse cell membranes, releasing intracellular ATP, which reacts with the specific enzyme contained in the reagent to produce light. A fluorescence illuminometer is then used to detect the luminescence value. The number of microorganisms is proportional to the luminescence value. Since all living cells contain a constant amount of ATP, the ATP content can clearly indicate the amount of microorganisms and other biological residues in the sample, and is used to judge the hygiene status.

Instrument Applications

The ATP fluorescence detector is widely used in bacterial and microbial detection, medicine and health, food safety, market law enforcement, surface cleanliness detection, medical epidemic prevention, water quality and water administration, production line hygiene, industrial water treatment, environmental protection testing, customs entry-exit quarantine and other law enforcement departments, and many other industries.

Software Platform

The instrument also has WiFi networking, Bluetooth transmission and data cable connection to a computer, providing multiple upload methods, and is equipped with an online supervision platform. Historical data can be uploaded wirelessly to the software platform for historical data analysis and statistics. Historical data can be displayed as curve trend charts, pie charts, etc. Through the platform, users can realize hygiene monitoring and plan management. At the same time, data can be uploaded point-to-point and instantly to the mobile terminal in Excel format, which is convenient for mobile phone sharing and reading.

Instrument Characteristics

  • Practicality — upper and lower limits can be set according to environmental detection requirements, enabling rapid data assessment and early warning, and rapid screening of surface cleanliness.
  • High sensitivity — detection accuracy 1×10⁻¹⁵ to 1×10⁻¹⁸ mol ATP.
  • Fast speed — conventional culture methods take more than 18-24 h, while ATP takes only a dozen seconds.
  • Feasibility — there is a clear correlation between the number of microorganisms and the ATP contained in microorganisms. By detecting the ATP content, the number of microorganisms in the reaction can be indirectly derived.
  • Operability — traditional culture methods need to be operated in a laboratory by trained technicians, whereas ATP rapid cleanliness detection is very simple to operate and can be performed on site by ordinary staff after simple training.
  • Strong interactivity — Android high-sensitivity touch operation and a high-speed data processing chip provide faster running speed and stronger stability.

Main Parameters

  • Display: 3.5-inch high-precision graphic touch screen.
  • Operating program: Android system.
  • Processor: ARM Cortex-A7, main frequency 1.88 GHz, 4-core high-speed chip.
  • Detection accuracy: 1×10⁻¹⁵ to 1×10⁻¹⁸ mol ATP.
  • Detection range: 0 to 999,999 RLU.
  • Detection interference: ±5% or ±5 RLUs.
  • ATP recovery rate: 90%-110%.
  • Detection time: 15 s.
  • Detection mode: RLU.
  • Upper limit and lower limit can be set arbitrarily.
  • Automatic qualification / non-qualification judgment.
  • Built-in self-calibration light source.
  • 30 s self-check at startup.
  • Stable liquid luciferase.
  • Wetted integrated collection swab.
  • Operating temperature range: 5-40℃.
  • Operating humidity range: 20%-85%.
  • Data storage: 4 GB memory, can store 100,000 sets of data.
  • Equipped with a miniUSB interface, allowing results to be uploaded to a PC.
  • With Wi-Fi, results can be uploaded wirelessly to the data analysis platform.
  • A dedicated software driver USB flash drive is also provided instead of a traditional CD.
  • Instrument dimensions (W×H×D): 188 mm × 77 mm × 37 mm.
  • 3.7 V, 3000 mAh lithium battery.
  • Standby state (20℃): 6 months.
  • Chinese / English operation manual.

Standard Configuration

Standard configuration: ATP fluorescence detector (handheld) main unit, aluminum alloy carrying case, driver USB flash drive, PC data cable, data analysis software, Chinese operation manual.

The video is currently in production, please stay tuned......

Shandong Horde Electronic Technology Co., Ltd.

  • Phone:008619053605658

  • Email:salesmanager@hordeinstrument.com

whatsapp

Copyright © Shandong Horde Electronic Technology Co., Ltd. All Rights Reserved.
Disclaimer: This website cannot identify the intellectual property rights of uploaded images or text. If there is any infringement, please notify us in a timely manner, and this website will review and delete it as soon as possible.

Phone

008619053605658

Contact
Top